VMware HCI Master Specialist 5V0-21.21 Dumps in PDF

Free VMware 5V0-21.21 Real Questions (page: 11)

An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen? Options:

  1. vSAN network diagnostic mode is not enabled.
  2. vSAN proactive tests haven't been run yet.
  3. vSAN performance service is turned off.
  4. vSAN performance verbose mode is not enabled.

Answer(s): C

Explanation:

Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.


Reference:

https://core.vmware.com/resource/troubleshooting-vsan-performance#_Toc536646873



In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?
Options:

  1. SFTT = 0
  2. SFTT = 1
  3. PFTT = 1
  4. PFTT = 0

Answer(s): A


Reference:

https://www.delltechnologies.com/asset/en-us/products/converged-infrastructure/technical-support/h15275-vxrail-planning-guide-virtual-san-stretched-cluster.pdf (5)



After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).
Which step should be taken to resolve this issue? Options:

  1. Configure vmk0 with IP address on the same range as that of vmk1.
  2. Tag the vmk0 for vSAN traffic.
  3. Configure vmk1 with IP address on the different network than that of vmk0.
  4. Tag the vmk1 for Witness traffic

Answer(s): C

Explanation:

Click on next and assign the IP address for the Witnesspg vmkernel interface. The vmk1 interface cannot be configured with an IP address on the same range as that of vmk0. This is because Management traffic and vSAN traffic use the default TCP/IP stack. If both vmk0 and vmk1 are configured on the same range, a multihoming condition will occur and vSAN traffic will flow from vmk0, rather than vmk1.


Reference:

http://www.vmwarearena.com/vsan-stretched-cluster-how-to-configure-vsan-witness-appliance/



During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.
Which two commands must be run to extend the time? (Choose two.) Options:

  1. /etc/init.d/vsanmgmtd restart
  2. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50
  3. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80
  4. /etc/init.d/clomd restart
  5. /etc/init.d/vsanobserver restart

Answer(s): C,D


Reference:

https://kb.vmware.com/s/article/2075456



A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. During the discovery phase, the consultant found the following information about the existing environment:

* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.
* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.
* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.
* The vSAN Cluster has the following configuration:
- vSAN version: 6.6.1
- Number of vSAN nodes: 10
- Encryption: enabled
- Deduplication and Compression: enabled
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- VMware vSphere ESXi version: 6.5 Update 3
- CPU: 2 processors, 20 cores
- RAM: 768GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE

Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)
Options:

  1. The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.
  2. The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.
  3. The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).
  4. The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.
  5. The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).
  6. The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.

Answer(s): B,D,E



Share your comments for VMware 5V0-21.21 exam with other users:

B
Bilal
8/22/2023 6:33:00 AM

i did attend the required cources and i need to be sure that i am ready to take the exam, i would ask you please to share the questions, to be sure that i am fit to proceed with taking the exam.

J
John
11/12/2023 8:48:00 PM

why only give explanations on some, and not all questions and their respective answers?

B
Biswa
11/20/2023 8:50:00 AM

refresh db knowledge

S
Shalini Sharma
10/17/2023 8:29:00 AM

interested for sap certification

E
ethan
9/24/2023 12:38:00 PM

could you please upload practice questions for scr exam ?

V
vijay joshi
8/19/2023 3:15:00 AM

please upload free oracle cloud infrastructure 2023 foundations associate exam braindumps

A
Ayodele Talabi
8/25/2023 9:25:00 PM

sweating! they are tricky

R
Romero
3/23/2022 4:20:00 PM

i never use these dumps sites but i had to do it for this exam as it is impossible to pass without using these question dumps.

J
John Kennedy
9/20/2023 3:33:00 AM

good practice and well sites.

N
Nenad
7/12/2022 11:05:00 PM

passed my first exam last week and pass the second exam this morning. thank you sir for all the help and these brian dumps.

L
Lucky
10/31/2023 2:01:00 PM

does anyone who attended exam csa 8.8, can confirm these questions are really coming ? or these are just for practicing?

P
Prateek
9/18/2023 11:13:00 AM

kindly share the dumps

I
Irfan
11/25/2023 1:26:00 AM

very nice content

P
php
6/16/2023 12:49:00 AM

passed today

D
Durga
6/23/2023 1:22:00 AM

hi can you please upload questions

J
JJ
5/28/2023 4:32:00 AM

please upload quetions

N
Norris
1/3/2023 8:06:00 PM

i passed my exam thanks to this braindumps questions. these questions are valid in us and i highly recommend it!

A
abuti
7/21/2023 6:10:00 PM

are they truely latest

C
Curtis Nakawaki
7/5/2023 8:46:00 PM

questions appear contemporary.

V
Vv
12/2/2023 6:31:00 AM

good to prepare in this site

P
praveenkumar
11/20/2023 11:57:00 AM

very helpful to crack first attempt

A
asad Raza
5/15/2023 5:38:00 AM

please upload this exam

R
Reeta
7/17/2023 5:22:00 PM

please upload the c_activate22 dump questions with answer

W
Wong
12/20/2023 11:34:00 AM

q10 - the answer should be a. if its c, the criteria will meet if either the prospect is not part of the suppression lists or if the job title contains vice president

D
david
12/12/2023 12:38:00 PM

this was on the exam as of 1211/2023

T
Tink
7/24/2023 9:23:00 AM

great for prep

J
Jaro
12/18/2023 3:12:00 PM

i think in question 7 the first answer should be power bi portal (not power bi)

9
9eagles
4/7/2023 10:04:00 AM

on question 10 and so far 2 wrong answers as evident in the included reference link.

T
Tai
8/28/2023 5:28:00 AM

wonderful material

V
VoiceofMidnight
12/29/2023 4:48:00 PM

i passed!! ...but barely! got 728, but needed 720 to pass. the exam hit me with labs right out of the gate! then it went to multiple choice. protip: study the labs!

A
A K
8/3/2023 11:56:00 AM

correct answer for question 92 is c -aws shield

N
Nitin Mindhe
11/27/2023 6:12:00 AM

great !! it is really good

B
BailleyOne
11/22/2023 1:45:00 AM

explanations for the answers are to the point.

P
patel
10/25/2023 8:17:00 AM

how can rea next

AI Tutor 👋 I’m here to help!