During creation of a new Organization for All Applications in VCF Automation, which four NSX constructs are automatically configured at the regional networking step? (Choose four.)
Answer(s): A,B,E,G
Comprehensive and DetailedThe VCF Automation Networking Guide (9.0) documents that when an Organization for All Applications is created, networking constructs are provisioned automatically to provide immediate connectivity. Specifically, “During region creation, the system automatically deploys a Default VPC, a Provider Tier-0 Gateway, a VPC connectivity profile, and default SNAT rules to enable outbound access.” .DNAT rules are not provisioned by default (they must be configured for inbound services). Likewise, NSX Transit Gateway is a multi-region design element, not automatically deployed for a single org setup. A VDS is a vSphere construct and not part of the NSX automation performed at this stage. Therefore, the automatically created items are: Default VPC (A), Provider Tier-0 Gateway (B), SNAT rule (E), and VPC Connectivity Profile (G).
An administrator creates a custom alert in VCF Operations for a VM with a symptom definition: “Read Latency > 1 ms.” The alert should trigger immediately once the symptom condition occurs. What additional step is required to ensure the alert functions?
Answer(s): A
Comprehensive and DetailedThe VCF Operations 9.0 Monitoring Guide specifies: “For any alert definition to be active in the environment, it must be associated with and enabled in an Active Policy.” . Creating symptom and alert definitions only defines conditions; they do not generate alerts until policies include them. REST notification plugins or payload templates are used for outbound integrations, not for enabling alerts. A super metric is only needed for custom composite KPIs, not for native read latency which is a standard metric already available. Therefore, the required step is to enable the alert in an Active Policy so that when the symptom triggers (latency > 1 ms), the alert activates.
A large corporation recently experienced a power outage at one of its primary data centers resulting in service disruption for customers in that region. An administrator is tasked to assess the current infrastructure and propose a plan to improve resiliency.Current configuration:Single-site vSAN Express Storage Architecture (ESA) cluster12 hostsCluster resource utilization (CPU, memory, and storage) is under 30%Which solution would improve resiliency and minimize service disruption in data center outages with a recovery point objective (RPO) of zero without requiring additional hosts?
The VCF 9.0 Design Guide highlights that for resiliency across sites with RPO = 0, the recommended approach is a vSAN Stretched Cluster. Documentation states: “Stretched clusters provide site-level resilience by mirroring data across two fault domains (sites). In the event of a full site outage, workloads remain available with no data loss (RPO = 0).” Relocating six hosts to another site creates the two fault domains required for vSAN Stretched Cluster. Options B and C provide backup or redundancy but not synchronous replication with zero RPO. Option D (fault domains) protects against host/rack failures, not entire data center loss. Therefore, the correct solution is to relocate hosts and configure a stretched cluster.
An organization wants to enable Service and Application Discovery across their VMware Cloud Foundation (VCF) fleet. Which optional VMware Cloud Foundation (VCF) solution must the administrator enable or deploy to facilitate this capability?
Answer(s): D
The VCF Operations for Networks (formerly vRNI) enables Application Discovery and Network Visibility. According to VCF 9.0: “Operations for Networks provides flow-based application discovery, dependency mapping, and security planning. This allows administrators to visualize application topology and relationships across the VCF fleet.” By contrast, VCF Operations for Logs provides log aggregation, while the Collector provides integration for metrics, not discovery. The vSphere Supervisor enables Kubernetes workloads, not application discovery. Therefore, to achieve Service and Application Discovery, administrators must deploy VCF Operations for Networks.
An administrator is responsible for monitoring VMware vSAN performance across a VMware Cloud Foundation (VCF) instance. The administrator confirms VCF Operations is configured correctly. When viewing Storage Operations, the vSAN Cluster Performance widget is not displaying any dat a. What additional configuration should the administrator complete to ensure the widget displays data?
According to the VCF 9.0 Operations and vSAN Integration Guide, performance metrics in the vSAN Cluster Performance widget are only available when the vSAN Performance Service is enabled. The documentation states:“The vSAN Performance Service must be enabled in vCenter Server for each vSAN cluster to collect and visualize performance statistics in VCF Operations. Without this service, performance dashboards and widgets will not display data.”Option A (Support Insight) relates to telemetry with VMware, not performance widgets.Option B (Cloud proxy as Collector) is required for general collection but not specific to vSAN widget visibility.Option C (SMART data collection) provides disk health analytics, not cluster-level performance stats.Option D is correct, because enabling the vSAN Performance Service ensures that VCF Operations receives and displays data in the vSAN Performance dashboards.Therefore, the administrator must enable the vSAN Performance Service for all vSAN clusters in vCenter.
An administrator is tasked to configure network connectivity to the organization's corporate network for their container workloads to be deployed on VMware Kubernetes Service (VKS) clusters backed by VMware NSX networking on a new VMware Cloud Foundation (VCF) deployment. Which gateway connectivity type should the administrator deploy?
The VMware Cloud Foundation 9.0 networking design documentation specifies that container workloads running on VMware Kubernetes Service (VKS) with NSX networking require external connectivity via a Centralized Connectivity model. This is implemented using an NSX Tier-0 (T0) Gateway which provides north-south routing to the corporate physical network.The guide states: “In VKS deployments backed by NSX networking, workloads achieve external reachability through a centralized Tier-0 Gateway, ensuring integration with corporate networking and enterprise services.” This model ensures traffic consolidation, policy enforcement, and simplified routing for Kubernetes workloads.Round-robin Connectivity is not a supported NSX gateway connectivity model.Distributed Connectivity refers to east-west NSX overlay communication, not north-south connectivity.Physical Connectivity is not precise, as workloads do not connect directly to the physical network; instead, they use logical routing.Centralized Connectivity is the correct model, where the T0 Gateway centralizes external routing for container workloads.
VMware Cloud Foundation 9.0 – NSX Networking and VKS Deployment Guide (Tier-0 Gateway connectivity model)..
What is the purpose of Istio Service Mesh?
Answer(s): B
The VCF 9.0 Service Mesh Integration Guide defines Istio as: “Istio Service Mesh provides an infrastructure layer that transparently handles service-to-service communication, securing, observing, and controlling traffic between microservices.” The key purpose is enabling structured and observable communication between applications. While Istio includes discovery and load balancing, those are features, not the overarching purpose. A centralized routing table (Option D) is not the core definition. VMware documentation highlights Istio’s role in service-to-service communication, observability, and policy enforcement within the service mesh. Therefore, the correct answer is B.
An administrator is deciding on a storage solution to create the first management workload domain for a new VMware Cloud Foundation (VCF) instance. Which three storage solutions can be used as principal storage? (Choose three.)
Answer(s): C,D,E
The VCF 9.0 Architecture Guide outlines valid principal storage options for the management domain. It states: “The management domain must be deployed using vSAN, NFS, or Fibre Channel (FC). Supported protocols include NFSv3 and VMFS on FC.” vSAN (including OSA) is the default recommended option, but NFSv3 and VMFS on FC are also supported for environments where external storage arrays are required.NVMe/TCP and vVols are not supported for the initial management domain’s principal storage. vVols may be used in workload domains after deployment, but they are not a supported foundation for the management domain. Therefore, the three correct storage solutions for the first management workload domain are: VMFS on FC, NFSv3, and vSAN OSA.
Share your comments for VMware 2V0-17.25 exam with other users:
are these brain dumps sufficient enough to go write exam after practicing them? or does one need more material this wont be enough?
i did attend the required cources and i need to be sure that i am ready to take the exam, i would ask you please to share the questions, to be sure that i am fit to proceed with taking the exam.
why only give explanations on some, and not all questions and their respective answers?
refresh db knowledge
interested for sap certification
could you please upload practice questions for scr exam ?
please upload free oracle cloud infrastructure 2023 foundations associate exam braindumps
sweating! they are tricky
i never use these dumps sites but i had to do it for this exam as it is impossible to pass without using these question dumps.
good practice and well sites.
passed my first exam last week and pass the second exam this morning. thank you sir for all the help and these brian dumps.
does anyone who attended exam csa 8.8, can confirm these questions are really coming ? or these are just for practicing?
kindly share the dumps
very nice content
passed today
hi can you please upload questions
please upload quetions
i passed my exam thanks to this braindumps questions. these questions are valid in us and i highly recommend it!
are they truely latest
questions appear contemporary.
good to prepare in this site
very helpful to crack first attempt
please upload this exam
please upload the c_activate22 dump questions with answer
q10 - the answer should be a. if its c, the criteria will meet if either the prospect is not part of the suppression lists or if the job title contains vice president
this was on the exam as of 1211/2023
great for prep
i think in question 7 the first answer should be power bi portal (not power bi)
on question 10 and so far 2 wrong answers as evident in the included reference link.
wonderful material
i passed!! ...but barely! got 728, but needed 720 to pass. the exam hit me with labs right out of the gate! then it went to multiple choice. protip: study the labs!
correct answer for question 92 is c -aws shield
great !! it is really good
explanations for the answers are to the point.
Keeping this site free takes real effort. We constantly battle automated scraping and unauthorized content copying. A quick account helps us protect the community and keep the site free.
To continue studying for your 2V0-17.25, please sign in or create a free account.