VMware 2V0-17.25 Exam (page: 2)
VMware Cloud Foundation 9.0 Administrator
Updated on: 29-Mar-2026

Viewing Page 2 of 9

During creation of a new Organization for All Applications in VCF Automation, which four NSX constructs are automatically configured at the regional networking step? (Choose four.)

  1. A Default Virtual Private Cloud (VPC)
  2. A Provider Tier-0 Gateway
  3. An outbound Destination Network Address Translation (DNAT) rule
  4. An NSX Transit Gateway
  5. An outbound Source Network Address Translation (SNAT) rule
  6. A Virtual Distributed Switch (VDS)
  7. A Virtual Private Cloud (VPC) connectivity profile

Answer(s): A,B,E,G

Explanation:

Comprehensive and Detailed
The VCF Automation Networking Guide (9.0) documents that when an Organization for All Applications is created, networking constructs are provisioned automatically to provide immediate connectivity. Specifically, "During region creation, the system automatically deploys a Default VPC, a Provider Tier-0 Gateway, a VPC connectivity profile, and default SNAT rules to enable outbound access." .
DNAT rules are not provisioned by default (they must be configured for inbound services). Likewise, NSX Transit Gateway is a multi-region design element, not automatically deployed for a single org setup. A VDS is a vSphere construct and not part of the NSX automation performed at this stage. Therefore, the automatically created items are: Default VPC (A), Provider Tier-0 Gateway (B), SNAT rule (E), and VPC Connectivity Profile (G).



An administrator creates a custom alert in VCF Operations for a VM with a symptom definition:
"Read Latency > 1 ms." The alert should trigger immediately once the symptom condition occurs.
What additional step is required to ensure the alert functions?

  1. Enable the alert in an Active Policy.
  2. Create a new Payload Template.
  3. Create an instance of the REST Notification Plugin.
  4. Create and enable a super metric for read latency in the Active Policy.

Answer(s): A

Explanation:

Comprehensive and Detailed
The VCF Operations 9.0 Monitoring Guide specifies: "For any alert definition to be active in the environment, it must be associated with and enabled in an Active Policy." . Creating symptom and alert definitions only defines conditions; they do not generate alerts until policies include them. REST notification plugins or payload templates are used for outbound integrations, not for enabling alerts. A super metric is only needed for custom composite KPIs, not for native read latency which is a standard metric already available. Therefore, the required step is to enable the alert in an Active Policy so that when the symptom triggers (latency > 1 ms), the alert activates.



A large corporation recently experienced a power outage at one of its primary data centers resulting in service disruption for customers in that region. An administrator is tasked to assess the current infrastructure and propose a plan to improve resiliency.
Current configuration:
Single-site vSAN Express Storage Architecture (ESA) cluster 12 hosts
Cluster resource utilization (CPU, memory, and storage) is under 30% Which solution would improve resiliency and minimize service disruption in data center outages with a recovery point objective (RPO) of zero without requiring additional hosts?

  1. Relocate six ESX hosts to another data center and configure a vSAN Stretched Cluster.
  2. Deploy VMware Live Recovery to maintain an identical copy in a secondary site.
  3. Convert existing production workload to a 2 failures ­ RAID-1 storage policy.
  4. Configure the twelve ESX hosts into six fault domains.

Answer(s): A

Explanation:

The VCF 9.0 Design Guide highlights that for resiliency across sites with RPO = 0, the recommended approach is a vSAN Stretched Cluster. Documentation states: "Stretched clusters provide site-level resilience by mirroring data across two fault domains (sites). In the event of a full site outage,

workloads remain available with no data loss (RPO = 0)." Relocating six hosts to another site creates the two fault domains required for vSAN Stretched Cluster. Options B and C provide backup or redundancy but not synchronous replication with zero RPO. Option D (fault domains) protects against host/rack failures, not entire data center loss. Therefore, the correct solution is to relocate hosts and configure a stretched cluster.



An organization wants to enable Service and Application Discovery across their VMware Cloud Foundation (VCF) fleet.
Which optional VMware Cloud Foundation (VCF) solution must the administrator enable or deploy to facilitate this capability?

  1. vSphere Supervisor
  2. VCF Operations for Logs
  3. VCF Operations Collector
  4. VCF Operations for Networks

Answer(s): D

Explanation:

The VCF Operations for Networks (formerly vRNI) enables Application Discovery and Network Visibility. According to VCF 9.0: "Operations for Networks provides flow-based application discovery, dependency mapping, and security planning. This allows administrators to visualize application topology and relationships across the VCF fleet." By contrast, VCF Operations for Logs provides log aggregation, while the Collector provides integration for metrics, not discovery. The vSphere Supervisor enables Kubernetes workloads, not application discovery. Therefore, to achieve Service and Application Discovery, administrators must deploy VCF Operations for Networks.



An administrator is responsible for monitoring VMware vSAN performance across a VMware Cloud Foundation (VCF) instance. The administrator confirms VCF Operations is configured correctly.
When viewing Storage Operations, the vSAN Cluster Performance widget is not displaying any data. What additional configuration should the administrator complete to ensure the widget displays data?

  1. Enable Support Insight for all vSAN Clusters in vCenter.
  2. Select a Cloud proxy as Collector in the vSAN integration.
  3. Select "Enable SMART data collection" in the vCenter integration.
  4. Enable Performance Service for all vSAN Clusters in vCenter.

Answer(s): D

Explanation:

According to the VCF 9.0 Operations and vSAN Integration Guide, performance metrics in the vSAN Cluster Performance widget are only available when the vSAN Performance Service is enabled. The documentation states:
"The vSAN Performance Service must be enabled in vCenter Server for each vSAN cluster to collect and visualize performance statistics in VCF Operations. Without this service, performance dashboards and widgets will not display data."
Option A (Support Insight) relates to telemetry with VMware, not performance widgets. Option B (Cloud proxy as Collector) is required for general collection but not specific to vSAN widget visibility.
Option C (SMART data collection) provides disk health analytics, not cluster-level performance stats. Option D is correct, because enabling the vSAN Performance Service ensures that VCF Operations receives and displays data in the vSAN Performance dashboards. Therefore, the administrator must enable the vSAN Performance Service for all vSAN clusters in vCenter.



An administrator is tasked to configure network connectivity to the organization's corporate network for their container workloads to be deployed on VMware Kubernetes Service (VKS) clusters backed by VMware NSX networking on a new VMware Cloud Foundation (VCF) deployment.
Which gateway connectivity type should the administrator deploy?

  1. Round-robin Connectivity
  2. Distributed Connectivity
  3. Physical Connectivity
  4. Centralized Connectivity

Answer(s): D

Explanation:

The VMware Cloud Foundation 9.0 networking design documentation specifies that container workloads running on VMware Kubernetes Service (VKS) with NSX networking require external connectivity via a Centralized Connectivity model. This is implemented using an NSX Tier-0 (T0) Gateway which provides north-south routing to the corporate physical network. The guide states: "In VKS deployments backed by NSX networking, workloads achieve external reachability through a centralized Tier-0 Gateway, ensuring integration with corporate networking and enterprise services." This model ensures traffic consolidation, policy enforcement, and simplified routing for Kubernetes workloads.
Round-robin Connectivity is not a supported NSX gateway connectivity model. Distributed Connectivity refers to east-west NSX overlay communication, not north-south connectivity.
Physical Connectivity is not precise, as workloads do not connect directly to the physical network; instead, they use logical routing.
Centralized Connectivity is the correct model, where the T0 Gateway centralizes external routing for container workloads.


Reference:

VMware Cloud Foundation 9.0 ­ NSX Networking and VKS Deployment Guide (Tier-0 Gateway connectivity model).



What is the purpose of Istio Service Mesh?

  1. Provides service discovery across multiple clusters.
  2. Provides an infrastructure layer that makes communication between applications possible, structured, and observable.
  3. Provides dynamic application load balancing and autoscaling across multiple clusters and sites.
  4. Provides a centralized, global routing table to simplify and optimize traffic management.

Answer(s): B

Explanation:

The VCF 9.0 Service Mesh Integration Guide defines Istio as: "Istio Service Mesh provides an infrastructure layer that transparently handles service-to-service communication, securing, observing, and controlling traffic between microservices." The key purpose is enabling structured and observable communication between applications.
While Istio includes discovery and load balancing, those are features, not the overarching purpose. A centralized routing table (Option D) is not the core definition. VMware documentation highlights Istio's role in service-to-service communication, observability, and policy enforcement within the service mesh. Therefore, the correct answer is B.



An administrator is deciding on a storage solution to create the first management workload domain for a new VMware Cloud Foundation (VCF) instance.
Which three storage solutions can be used as principal storage? (Choose three.)

  1. NVMe/TCP
  2. Virtual Volumes (vVols)
  3. VMFS on Fibre Channel (FC)
  4. NFSv3
  5. vSAN OSA

Answer(s): C,D,E

Explanation:

The VCF 9.0 Architecture Guide outlines valid principal storage options for the management domain. It states: "The management domain must be deployed using vSAN, NFS, or Fibre Channel (FC). Supported protocols include NFSv3 and VMFS on FC." vSAN (including OSA) is the default recommended option, but NFSv3 and VMFS on FC are also supported for environments where external storage arrays are required.
NVMe/TCP and vVols are not supported for the initial management domain's principal storage. vVols may be used in workload domains after deployment, but they are not a supported foundation for the management domain. Therefore, the three correct storage solutions for the first management workload domain are: VMFS on FC, NFSv3, and vSAN OSA.



Viewing Page 2 of 9



Share your comments for VMware 2V0-17.25 exam with other users:

Tyron 9/8/2023 12:12:00 AM

so far it is really informative
Anonymous


beast 7/30/2023 2:22:00 PM

hi i want it please please upload it
Anonymous


Mirex 5/26/2023 3:45:00 AM

am preparing for exam ,just nice questions
Anonymous


exampei 8/7/2023 8:05:00 AM

please upload c_tadm_23 exam
TURKEY


Anonymous 9/12/2023 12:50:00 PM

can we get tdvan4 vantage data engineering pdf?
UNITED STATES


Aish 10/11/2023 5:51:00 AM

want to clear the exam.
INDIA


Smaranika 6/22/2023 8:42:00 AM

could you please upload the dumps of sap c_sac_2302
INDIA


Blessious Phiri 8/15/2023 1:56:00 PM

asm management configuration is about storage
Anonymous


Lewis 7/6/2023 8:49:00 PM

kool thumb up
UNITED STATES


Moreece 5/15/2023 8:44:00 AM

just passed the az-500 exam this last friday. most of the questions in this exam dumps are in the exam. i bought the full version and noticed some of the questions which were answered wrong in the free version are all corrected in the full version. this site is good but i wish the had it in an interactive version like a test engine simulator.
Anonymous


Terry 5/24/2023 4:41:00 PM

i can practice for exam
Anonymous


Emerys 7/29/2023 6:55:00 AM

please i need this exam.
Anonymous


Goni Mala 9/2/2023 12:27:00 PM

i need the dump
Anonymous


Lenny 9/29/2023 11:30:00 AM

i want it bad, even if cs6 maybe retired, i want to learn cs6
HONG KONG


MilfSlayer 12/28/2023 8:32:00 PM

i hate comptia with all my heart with their "choose the best" answer format as an argument could be made on every question. they say "the "comptia way", lmao no this right here boys is the comptia way 100%. take it from someone whos failed this exam twice but can configure an entire complex network that these are the questions that are on the test 100% no questions asked. the pbqs are dead on! nice work
Anonymous


Swati Raj 11/14/2023 6:28:00 AM

very good materials
UNITED STATES


Ko Htet 10/17/2023 1:28:00 AM

thanks for your support.
Anonymous


Philippe 1/22/2023 10:24:00 AM

iam impressed with the quality of these dumps. they questions and answers were easy to understand and the xengine app was very helpful to use.
CANADA


Sam 8/31/2023 10:32:00 AM

not bad but you question database from isaca
MALAYSIA


Brijesh kr 6/29/2023 4:07:00 AM

awesome contents
INDIA


JM 12/19/2023 1:22:00 PM

answer to 134 is casb. while data loss prevention is the goal, in order to implement dlp in cloud applications you need to deploy a casb.
UNITED STATES


Neo 7/26/2023 9:36:00 AM

are these brain dumps sufficient enough to go write exam after practicing them? or does one need more material this wont be enough?
SOUTH AFRICA


Bilal 8/22/2023 6:33:00 AM

i did attend the required cources and i need to be sure that i am ready to take the exam, i would ask you please to share the questions, to be sure that i am fit to proceed with taking the exam.
Anonymous


John 11/12/2023 8:48:00 PM

why only give explanations on some, and not all questions and their respective answers?
UNITED STATES


Biswa 11/20/2023 8:50:00 AM

refresh db knowledge
Anonymous


Shalini Sharma 10/17/2023 8:29:00 AM

interested for sap certification
JAPAN


ethan 9/24/2023 12:38:00 PM

could you please upload practice questions for scr exam ?
HONG KONG


vijay joshi 8/19/2023 3:15:00 AM

please upload free oracle cloud infrastructure 2023 foundations associate exam braindumps
Anonymous


Ayodele Talabi 8/25/2023 9:25:00 PM

sweating! they are tricky
CANADA


Romero 3/23/2022 4:20:00 PM

i never use these dumps sites but i had to do it for this exam as it is impossible to pass without using these question dumps.
UNITED STATES


John Kennedy 9/20/2023 3:33:00 AM

good practice and well sites.
Anonymous


Nenad 7/12/2022 11:05:00 PM

passed my first exam last week and pass the second exam this morning. thank you sir for all the help and these brian dumps.
INDIA


Lucky 10/31/2023 2:01:00 PM

does anyone who attended exam csa 8.8, can confirm these questions are really coming ? or these are just for practicing?
HONG KONG


Prateek 9/18/2023 11:13:00 AM

kindly share the dumps
UNITED STATES