Which statement is correct about the VXLAN data plane?
Answer(s): C
VXLAN (Virtual Extensible LAN) uses an overlay encapsulation method to carry Layer-2 frames over an IP underlay. This functionality is part of the data plane, which is responsible for packet forwarding and encapsulation/decapsulation."In an EVPN-VXLAN fabric, the control plane (via BGP EVPN) learns and advertises MAC and IP information, while the data plane encapsulates and forwards traffic using VXLAN tunnels between VTEPs."Option A is incorrect: IP learning happens in the control plane, not the data plane.Option B is incorrect: MAC advertisement is done in the control plane through EVPN route types.Option D is incorrect: MAC learning is handled by EVPN control plane, not the VXLAN data plane.Option C is correct: the VXLAN data plane encapsulates the traffic in UDP tunnels between VTEPs.
Juniper Mist AI for Wired EVPN-VXLAN OverviewJuniper Validated Design EVPN-VXLAN Control and Data Plane SeparationJunos OS EVPN-VXLAN Deployment Guide
What are two unique advantages about configuration automation in Wired Assurance? (Choose two.)
Answer(s): A,C
Wired Assurance in Mist Cloud provides automated configuration for Juniper EX Series switches. The automation is built on open APIs and supports programmable workflows, which allow seamless integration with external systems and reduce manual configuration errors."Wired Assurance leverages 100% open APIs, enabling integration with third-party automation and orchestration tools. Combined with programmable workflows, this provides a consistent and scalable automation framework for switch deployment and management."Option A (100% open APIs): Correct -- APIs enable automation and external integration.Option C (programmable workflows): Correct -- workflows automate repetitive tasks and provisioning.Option B (client SLEs): Incorrect -- this is part of user experience monitoring, not automation.Option D (switch insights): Incorrect -- this relates to telemetry and visibility, not automation.
Juniper Mist AI for Wired Wired Assurance OverviewJuniper Mist AI for Wired Switch Automation and APIs GuideJuniper Validated Design Mist Wired Automation Best Practices
In Juniper Mist cloud services, service level expectation (SLE) telemetry is collected from every device and stored for up to how long?
Answer(s): A
Juniper Mist AI collects telemetry for Service Level Expectations (SLEs) across wired and wireless devices. This telemetry includes metrics such as time-to-connect, throughput, coverage, and switch performance."Service Level Expectation (SLE) data is collected from every device and stored for up to one month in the Mist Cloud. This allows administrators to analyze historical performance trends and troubleshoot issues based on real-time and historical data." Option B (2 months): Incorrect -- data is not retained this long. Option C (7 days): Incorrect -- telemetry retention is longer. Option D (24 hours): Incorrect -- too short for Mist SLE analytics. Option A (1 month): Correct -- Mist Cloud retains SLE telemetry for 30 days (1 month).
Juniper Mist AI for Wired Service Level Expectations Overview Juniper Mist AI for Wired Telemetry and Data Retention Guide ===========
Which campus fabric architecture supports Layer 3 gateways at the distribution layer?
In Juniper's campus fabric architectures, the location of the Layer 3 gateway (IRB) differentiates between CRB and ERB models:Centrally-Routed Bridging (CRB): L3 gateways are placed at the core layer. Edge-Routed Bridging (ERB): L3 gateways are placed at the distribution layer, closer to the edge. "In the ERB model, Layer 2 gateways are deployed at the access layer, and Layer 3 gateways are deployed at the distribution layer."Option A (CRB): Incorrect -- L3 is at the core, not distribution. Option B (IP Clos): Incorrect -- in 3-stage Clos, L3 is pushed to the access layer. Option D (EVPN multihoming): Incorrect -- this is about redundancy, not gateway placement. Option C (ERB): Correct -- L3 gateways sit at the distribution layer in the ERB architecture.
Juniper Mist AI for Wired Campus Fabric Architecture ModelsJuniper Validated Design Core/Distribution CRB vs ERB Gateways Junos OS EVPN-VXLAN Campus Fabric Deployment Guide
You have deployed your switches and need to provide a unique hostname on each switch. Which Mist dashboard option allows you to accomplish this task?
In Juniper Mist Cloud, there are multiple configuration scopes:Organization-level templates apply globally.Site-level configuration applies across all devices in a site. Individual switch configuration is used to define unique, device-specific attributes such as hostname, management IP, or local overrides."Templates and site-level configuration ensure consistency across devices, while individual switch configuration is used to assign unique values such as hostnames." Option A: Incorrect -- org templates define common config, not hostnames. Option B: Incorrect -- site configs are shared across all switches in the site. Option D: Incorrect -- device profiles apply settings like port policies or authentication, not hostnames.Option C: Correct -- individual switch configuration is the correct place to assign hostnames uniquely per device.
Juniper Mist AI for Wired Switch Configuration Hierarchy Juniper Mist Documentation Device-Level Configuration in Wired Assurance ===========
Which two statements are correct about the campus fabric core-distribution architecture? (Choose two.)
Answer(s): A,D
In a core-distribution campus fabric model, the EVPN-VXLAN overlay is established only between the core and distribution tiers. The access switches are not part of the EVPN fabric; they connect upstream to distribution but do not run VXLAN tunnels. "In the core-distribution campus fabric, only the core and distribution layers participate in the EVPN- VXLAN topology. The access layer connects to the distribution switches and forwards traffic but does not take part in the EVPN-VXLAN fabric."Option A: Correct -- EVPN-VXLAN is built between core and distribution tiers. Option B: Incorrect -- both core and distribution participate, not just core. Option C: Incorrect -- access switches are excluded from EVPN-VXLAN participation.Option D: Correct -- the access layer does not participate in EVPN-VXLAN.
Juniper Mist AI for Wired Campus Fabric Core-Distribution Architecture Juniper Validated Design EVPN-VXLAN Campus Deployment Models Junos OS EVPN Campus Fabric Design Guide
What information does Mist use to determine if the port is classified as an uplink? (Choose two.)
Juniper Mist automatically classifies ports to simplify visibility and automation within Wired Assurance. The Mist cloud analyzes port telemetry and link behavior to determine port roles, including uplinks."Mist uses machine learning and switch telemetry to automatically detect uplinks by analyzing traffic behavior and topology information. Uplink ports typically exhibit higher TX/RX utilization and are identified as spanning-tree root or forwarding ports connecting upstream devices." Option A: Correct -- Mist examines traffic statistics. Ports with significantly higher TX/RX utilization relative to others are likely uplinks.Option B: Incorrect -- MTU size is not a classification criterion. Option C: Correct -- Mist uses STP information (root or designated port status) to identify uplinks. Option D: Incorrect -- port description fields are for administrative purposes only and are not used by Mist analytics.
Juniper Mist AI for Wired Port Role Classification and Telemetry Juniper Mist AI for Wired Automated Uplink Detection and Insights Juniper Wired Assurance Analytics Guide
Which two statements are correct about the EVPN-VXLAN control plane? (Choose two.)
Answer(s): B,C
In an EVPN-VXLAN fabric, the control plane operates over BGP EVPN and is responsible for distributing endpoint reachability information (MAC and IP) among VTEPs. The data plane, by contrast, performs encapsulation and forwarding."The EVPN control plane uses BGP to exchange MAC and IP address reachability information between VTEPs, enabling efficient forwarding and loop prevention without relying on flood-and- learn behavior."Option A: Incorrect -- encapsulation occurs in the data plane, not the control plane. Option B: Correct -- the control plane distributes MAC-to-VTEP mappings. Option C: Correct -- the control plane also distributes IP-to-MAC associations (Type 2 and Type 5 EVPN routes).Option D: Incorrect -- the control plane does not alter packet headers.
Juniper Mist AI for Wired EVPN-VXLAN OverviewJuniper Validated Design EVPN Control and Data Plane Operation Junos OS EVPN-VXLAN Implementation Guide
Share your comments for Juniper JN0-460 exam with other users:
good questions
good content
totally not correct answers. 21. you have one gcp account running in your default region and zone and another account running in a non-default region and zone. you want to start a new compute engine instance in these two google cloud platform accounts using the command line interface. what should you do? correct: create two configurations using gcloud config configurations create [name]. run gcloud config configurations activate [name] to switch between accounts when running the commands to start the compute engine instances.
kindly upload the dumps
still learning
excellent way to learn
help so much
understand sql col.
i would give 5 stars to this website as i studied for az-800 exam from here. it has all the relevant material available for preparation. i got 890/1000 on the test.
this is nice.
q55- the ridac workflow can be modified using flow designer, correct answer is d not a
by far this is the most accurate exam dumps i have ever purchased. all questions are in the exam. i saw almost 90% of the questions word by word.
i cleared the az-104 exam by scoring 930/1000 on the exam. it was all possible due to this platform as it provides premium quality service. thank you!
question # 232: accessibility, privacy, and innovation are not data quality dimensions.
looks wrong answer for 443 question, please check and update
great question
question: a user wants to start a recruiting posting job posting. what must occur before the posting process can begin? 3 ans: comment- option e is incorrect reason: as part of enablement steps, sap recommends that to be able to post jobs to a job board, a user need to have the correct permission and secondly, be associated with one posting profile at minimum
answer to question 72 is d [sys_user_role]
please provide the pdf
hey guys, just to let you all know that i cleared my 312-38 today within 1 hr with 100 questions and passed. thank you so much brain-dumps.net all the questions that ive studied in this dump came out exactly the same word for word "verbatim". you rock brain-dumps.net!!! section name total score gained score network perimeter protection 16 11 incident response 10 8 enterprise virtual, cloud, and wireless network protection 12 8 application and data protection 13 10 network défense management 10 9 endpoint protection 15 12 incident d
very helpful
useful questions
page :20 https://exam-dumps.com/snowflake/free-cof-c02-braindumps.html?p=20#collapse_453 q 74: true or false: pipes can be suspended and resumed. true. desc.: pausing or resuming pipes in addition to the pipe owner, a role that has the following minimum permissions can pause or resume the pipe https://docs.snowflake.com/en/user-guide/data-load-snowpipe-intro
i want hcia exam dumps
good training
very useful
yes need this exam dumps
these questions are a great eye opener
thank you for providing these questions and answers. they helped me pass my exam. you guys are great.
good knowledge
answer 10 should be a because only a new project will be created & the organization is the same.
can you please upload the dump again
is it legit questions from sap certifications ?
question 16 should be b (changing the connector settings on the monitor) pc and monitor were powered on. the lights on the pc are on indicating power. the monitor is showing an error text indicating that it is receiving power too. this is a clear sign of having the wrong input selected on the monitor. thus, the "connector setting" needs to be switched from hdmi to display port on the monitor so it receives the signal from the pc, or the other way around (display port to hdmi).
Keeping this site free takes real effort. We constantly battle automated scraping and unauthorized content copying. A quick account helps us protect the community and keep the site free.
To continue studying for your JN0-460, please sign in or create a free account.