Huawei HCSP-Field-Data Center Facility V1.0 H20-923_V1.0 Dumps in PDF

Free Huawei H20-923_V1.0 Real Questions (page: 1)

Which of the following is not a scenario-based solution for Huawei data center products?

  1. FusionDC800
  2. FusionDC1000
  3. FusionModule500
  4. FusionModule2000

Answer(s): A

Explanation:

Huawei’s scenario-based data center facility portfolio is organized around clearly defined solution families that map to typical deployment scenarios and site sizes. FusionModule500 and FusionModule2000 are smart modular data center solutions designed for standardized, fast deployment in equipment rooms and enterprise edge/branch scenarios. They integrate key subsystems such as power supply and distribution, cooling, monitoring, and optional fire protection into a modular architecture that reduces footprint and accelerates on-site delivery. Likewise, FusionDC1000 is Huawei’s prefabricated modular data center series, delivered as complete, factory-integrated modules that combine civil engineering elements with electromechanical infrastructure for rapid construction, predictable quality, and scalable expansion across different capacity tiers. In contrast, FusionDC800 is not used as a defined scenario-based solution name within Huawei’s mainstream data center facility solution lineup (where “FusionDC” offerings are represented by the FusionDC1000 series and “FusionModule” offerings by numbered FusionModule solutions). Therefore, FusionDC800 is the option that does not match Huawei’s scenario-based solution naming.



Huawei-developed intelligent rPDU (PDU2000M) can replace the original UIM20A expansion module. The rPDU can connect to the cabinet temperature/humidity sensors, smart U space managers, and door status sensors.

  1. True
  2. False

Answer(s): A

Explanation:

In Huawei smart module monitoring architecture, the UIM20A expansion module is traditionally used to increase device ports so cabinets can connect multiple intelligent components and sensors (for example, door status and environmental sensors). Huawei also provides the intelligent rPDU PDU2000M, whose main control module includes communications and DI interfaces designed to directly 接入 cabinet-level intelligent devices for centralized monitoring and management. In Huawei’s solution description for rPDU-monitoring networking, the PDU2000M is positioned to replace the expansion-module role, meaning that in applicable scenarios, cabinets can connect monitoring devices through the PDU2000M without deploying an additional UIM20A expansion module. This supports practical connections such as T/H sensors, smart U space managers, and door status/door-access related signals through the PDU2000M interfaces, and then these devices are managed/bound in the controller’s smart module view. Huawei O&M guidance also emphasizes avoiding duplicate connections (do not connect the same device to both UIM20A and PDU2000M), aligning with the replacement concept. (Scribd)



If the startup password authentication for a smart module is not complete, the ECC800-Pro WebUI and app cannot be used for commissioning.

  1. True
  2. False

Answer(s): A

Explanation:

In Huawei smart module commissioning and O&M workflows, startup password authentication is a mandatory security initialization step for the controller and its management channels. The ECC800-Pro provides WebUI and mobile app access for tasks such as device discovery, parameter setting, site configuration, alarm verification, and functional commissioning. Before these commissioning functions are allowed, the system requires completion of startup authentication actions, typically including initial password setup or password change, confirmation of authentication policies, and activation of secure access control. This prevents unauthorized users from entering the management plane during the critical initial stage when default credentials or incomplete security settings could exist. If startup password authentication is not completed, the platform restricts access to commissioning pages and app-based commissioning features, ensuring that configuration changes, device binding, and control operations cannot be executed until the controller is placed into a compliant, secured state. This design aligns with data center facility management best practices where commissioning must begin only after management access is hardened and auditable.



If the SPD indicator of a smart module is green, the SPD is running properly. If the SPD indicator is red, the SPD is faulty and must be replaced immediately.

  1. True
  2. False

Answer(s): A

Explanation:

In Huawei data center power distribution design, the SPD (Surge Protective Device) provides overvoltage surge protection for sensitive loads by diverting transient energy to ground through internal protection components. The SPD status indicator is used for O&M judgment of protection availability.
When the indicator is green, it indicates the SPD protection components are within normal working condition and the surge protection path remains effective.
When the indicator turns red, it typically means the SPD’s internal protection element has degraded or disconnected (end-of-life or failure after cumulative surges), and the device can no longer provide the rated protection level. In this condition, the distribution system is left exposed to surge risk, especially during thunderstorms, switching operations, or upstream disturbances. Therefore, Huawei O&M practice treats a red SPD indicator as a replacement trigger, requiring immediate corrective action: confirm alarm/status, ensure safe isolation following electrical safety procedures, and replace the SPD module to restore protection and maintain power system reliability.



Which of the following is the cabling mode of external power cables in IT scenarios of the FusionDC1000A?

  1. Bottom cabling
  2. End wall cabling
  3. Top cabling
  4. End door cabling

Answer(s): A

Explanation:

In the FusionDC1000A IT scenario, the external input power cables are designed to enter the power distribution system through dedicated cable inlets at the bottom of the Power PDB. During installation, the procedure requires opening the Power PDB, removing the plugs from the bottom cable holes, and routing the external input power cables into the cabinet through these bottom entries before arranging them along the nearby cable support/bridge inside the Power PDB area. After the cables are terminated (for example, L1/L2/L3/N and PE), the bottom cable entries are resealed using waterproof sealing materials to maintain enclosure protection performance. This bottom-entry method supports reliable mechanical routing for thick/armored power cables, reduces bending stress, helps maintain orderly segregation from signal cabling, and improves on-site safety by guiding high-current cables through a controlled inlet path. Therefore, the correct cabling mode for external power cables in FusionDC1000A IT scenarios is bottom cabling.



In IT scenarios, which of the following are the power supply and distribution components of the FusionDC1000A?

  1. SmartLi
  2. Power PDB
  3. Integrated UPS
  4. AC/DC power system

Answer(s): A,B,C

Explanation:

In the FusionDC1000A IT scenario, the power chain is built around an AC input, conditioned backup power, energy storage, and final distribution to the IT racks. Integrated UPS is the core power-conditioning component, providing voltage and frequency stabilization and uninterrupted supply during mains disturbances. The UPS works together with SmartLi, Huawei’s lithium battery system, which serves as the energy storage unit to sustain the load during outages and to support controlled shutdown or generator switchover. After UPS output, power is delivered to the IT loads through the Power PDB, which performs downstream distribution, branch protection, and organized cable termination toward rack PDUs or IT equipment feeders. By contrast, an AC/DC power system is typically associated with DC bus supply used in telecom-oriented or dedicated DC load scenarios, not the standard IT scenario architecture of FusionDC1000A that is centered on UPS plus battery plus AC distribution. Therefore, the correct components for IT scenarios are SmartLi, Power PDB, and Integrated UPS.



The default address of the WAN1 port on the ECC800-Pro is

  1. 192.168.0.10
  2. 192.168.248.10
  3. 192.168.248.1
  4. 192.168.8.10

Answer(s): D

Explanation:

In Huawei smart module commissioning, the ECC800-Pro controller provides a dedicated management access path through its WAN ports. For on-site startup commissioning, technicians typically connect a laptop directly to WAN1 and place the laptop IP address in the same subnet as the controller so they can open the WebUI and complete initial settings (time, network, device discovery, alarm checks, linkage tests, and parameter commissioning). The factory default IP address for WAN1 is 192.168.8.10, which is used as the initial access point before the address is planned and changed to match the customer’s management network. This default design supports quick “point-to-point” commissioning without depending on upstream switches, DHCP services, or enterprise IP planning at the very beginning of deployment. After login, Huawei commissioning practice is to harden access (password/authentication completion), then update network parameters and integrate the ECC800-Pro into the site monitoring network to enable continuous O&M, remote alarm reporting, and device management.



In a data center fire protection design, which approach best matches Huawei facility practice for protecting IT rooms while minimizing secondary damage to IT equipment?

  1. Use only portable extinguishers and rely on manual response
  2. Deploy a smoke detection system plus a clean-agent gas extinguishing system with interlock controls for automatic release
  3. Install a water sprinkler system as the only suppression method inside the IT white space
  4. Disable automatic suppression to avoid accidental discharge

Answer(s): B

Explanation:

Huawei data center facility design typically follows a layered fire protection concept: early detection, controlled alarm linkage, and suppression methods that protect equipment and ensure personnel safety. A smoke detection system (often combined with staged alarms) provides early warning so operators can verify events and initiate emergency procedures. For the IT white space, a clean-agent gas extinguishing system is preferred because it suppresses fire without leaving residue and significantly reduces the risk of corrosion or contamination compared with powder-based agents. The extinguishing system is normally integrated with linkage/interlock controls: audible/visual pre-discharge alarms, time delay, emergency abort, door access control logic, and HVAC shutdown or damper control to help maintain agent concentration. This coordinated mechanism reduces false discharge risk while preserving a reliable automatic response if a real fire develops. In contrast, relying only on manual extinguishers is too slow for rapid fire growth, and water sprinklers alone can cause substantial collateral damage to servers and power equipment.



Share your comments for Huawei H20-923_V1.0 exam with other users:

S
sam
7/17/2023 6:22:00 PM

cannot evaluate yet

N
nutz
7/20/2023 1:54:00 AM

a laptops wireless antenna is most likely located in the bezel of the lid

R
rajesh soni
1/17/2024 6:53:00 AM

good examplae to learn basic

T
Tanya
10/25/2023 7:07:00 AM

this is useful information

N
Nasir Mahmood
12/11/2023 7:32:00 AM

looks usefull

J
Jason
9/30/2023 1:07:00 PM

question 81 should be c.

T
TestPD1
8/10/2023 12:22:00 PM

question 18 : response isnt a ?

A
ally
8/19/2023 5:31:00 PM

plaese add questions

D
DIA
10/7/2023 5:59:00 AM

is dumps still valid ?

A
Annie
7/7/2023 8:33:00 AM

thanks for this

A
arnie
9/17/2023 6:38:00 AM

please upload questions

T
Tanuj Rana
7/22/2023 2:33:00 AM

please upload the question dump for professional machinelearning

F
Future practitioner
8/10/2023 1:26:00 PM

question 4 answer is c. this site shows the correct answer as b. "adopt a consumption model" is clearly a cost optimization design principle. looks like im done using this site to study!!!

A
Ace
8/3/2023 10:37:00 AM

number 52 answer is d

N
Nathan
12/17/2023 12:04:00 PM

just started preparing for my exam , and this site is so much help

C
Corey
12/29/2023 5:06:00 PM

question 35 is incorrect, the correct answer is c, it even states so: explanation: when a vm is infected with ransomware, you should not restore the vm to the infected vm. this is because the ransomware will still be present on the vm, and it will encrypt the files again. you should also not restore the vm to any vm within the companys subscription. this is because the ransomware could spread to other vms in the subscription. the best way to restore a vm that is infected with ransomware is to restore it to a new azure vm. this will ensure that the ransomware is not present on the new vm.

R
Rajender
10/18/2023 3:54:00 AM

i would like to take psm1 exam.

B
Blessious Phiri
8/14/2023 9:53:00 AM

cbd and pdb are key to the database

A
Alkaed
10/19/2022 10:41:00 AM

the purchase and download process is very much streamlined. the xengine application is very nice and user-friendly but there is always room for improvement.

D
Dave Gregen
9/4/2023 3:17:00 PM

please upload p_sapea_2023

S
Sarah
6/13/2023 1:42:00 PM

anyone use this? the question dont seem to follow other formats and terminology i have been studying im getting worried

S
Shuv
10/3/2023 8:19:00 AM

good questions

R
Reb974
8/5/2023 1:44:00 AM

hello are these questions valid for ms-102

M
Mchal
7/20/2023 3:38:00 AM

some questions are wrongly answered but its good nonetheless

S
Sonbir
8/8/2023 1:04:00 PM

how to get system serial number using intune

M
Manju
10/19/2023 1:19:00 PM

is it really helpful to pass the exam

L
LeAnne Hair
8/24/2023 12:47:00 PM

#229 in incorrect - all the customers require an annual review

A
Abdul SK
9/28/2023 11:42:00 PM

kindy upload

A
Aderonke
10/23/2023 12:53:00 PM

fantastic assessment on psm 1

S
SAJI
7/20/2023 2:51:00 AM

56 question correct answer a,b

R
Raj Kumar
10/23/2023 8:52:00 PM

thank you for providing the q bank

P
piyush keshari
7/7/2023 9:46:00 PM

true quesstions

B
B.A.J
11/6/2023 7:01:00 AM

i can´t believe ms asks things like this, seems to be only marketing material.

G
Guss
5/23/2023 12:28:00 PM

hi, could you please add the last update of ns0-527

AI Tutor 👋 I’m here to help!