VMware vSAN Specialist 5V0-22.21 Dumps in PDF

Free VMware 5V0-22.21 Real Questions (page: 12)

An organization is facing vSAN storage capacity challenges on one of their vSAN enabled clusters, while other vSAN enabled clusters are underutilized. The current vSAN version is 7.0 U1.
Which vSAN feature should be used to resolve this challenge in the quickest way?

  1. vSAN HCI Mesh
  2. vSAN Replication
  3. vSAN Stretched Clusters
  4. vSAN Datastore(s)

Answer(s): A


Reference:

https://docs.vmware.com/en/VMware-vSphere/7.0/rn/vmware-vsan-701-release-notes.html



An existing vSAN cluster has this specification:

-Four ESXi hosts with all flash configuration
-Each with two disk groups

Each disk group with one cache device and four capacity devices There are five more device slots available The CTO would like to provision new applications, and these will need more capacity and performance.
Which two methods may be used by the vSAN administrator to meet this goal? (Choose two.)

  1. Adding faster cache devices
  2. Adding one more disk group per host with the same configuration
  3. Replacing all cache devices by a larger device
  4. Adding an ESXi host with identical device configuration
  5. Replacing all capacity devices by a larger device

Answer(s): B,D


Reference:

https://core.vmware.com/resource/vmware-vsan-design-guide



An administrator has discovered that space utilized by VMs does not decrease after deleting files and folders within the VMs. The administrator needs to be able to reclaim this space.
Which action could the administrator take to accomplish this task?

  1. Disable Storage I/O Control for the vSAN cluster.
  2. Reboot the VM to recreate the swap file.
  3. Set the Object Space Reservation rule to 100%.
  4. Enable TRIM/UNMAP for the vSAN cluster.

Answer(s): D


Reference:

https://blogs.vmware.com/virtualblocks/2018/09/10/vmware-vsan-6-7u1-storage-reclamation-trim-unmap/



During yesterday’s business hours, a cache drive failed on one of the vSAN nodes. The administrator reached out to the manufacturer and received a replacement drive the following day. When the drive failed, vSAN started a resync to ensure the health of data, and all objects are showing a healthy and compliant state. The vSAN administrator needs to replace the failed cache drive.
Which set of steps should the vSAN administrator take?

  1. Remove the existing vSAN disk group, and physically replace the device. Then, check to verify that the ESXi host automatically detects the new device. Afterwards, manually recreate the Disk Group.
  2. Physically replace the failed cache device, and vSAN will automatically create a new disk group. Then, remove the disk group with the failed device.
  3. Physically replace the failed cache device, and vSAN will automatically allocate the storage. Then, rebalance the cache layer.
  4. Place the disk group into maintenance mode, and select Full Data Migration. Then, physically replace the failed cache device. Afterwards, vSAN will rebuild the disk group automatically.

Answer(s): B


Reference:

https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-monitoring.doc/GUID-95E5DAF9-FE36-497B-90B4- DB1CA05FE935.html



A vSphere administrator wants to use vSphere Lifecycle Manager (vLCM) to manage a vSAN cluster with one desired image. When creating the new cluster, the administrator chooses “Manage all hosts in the cluster with a single image”.
Which option is NOT available when setting up the cluster image?

  1. Import image from new host
  2. Import image from an existing host in the vCenter inventory
  3. Import baseline from vSphere Lifecycle Manager
  4. Compose a new image

Answer(s): D


Reference:

https://blogs.vmware.com/virtualblocks/2020/06/02/vsphere-lifecycle-manager-on-hpe/



Share your comments for VMware 5V0-22.21 exam with other users:

T
TestPD1
8/10/2023 12:22:00 PM

question 18 : response isnt a ?

A
ally
8/19/2023 5:31:00 PM

plaese add questions

D
DIA
10/7/2023 5:59:00 AM

is dumps still valid ?

A
Annie
7/7/2023 8:33:00 AM

thanks for this

A
arnie
9/17/2023 6:38:00 AM

please upload questions

T
Tanuj Rana
7/22/2023 2:33:00 AM

please upload the question dump for professional machinelearning

F
Future practitioner
8/10/2023 1:26:00 PM

question 4 answer is c. this site shows the correct answer as b. "adopt a consumption model" is clearly a cost optimization design principle. looks like im done using this site to study!!!

A
Ace
8/3/2023 10:37:00 AM

number 52 answer is d

N
Nathan
12/17/2023 12:04:00 PM

just started preparing for my exam , and this site is so much help

C
Corey
12/29/2023 5:06:00 PM

question 35 is incorrect, the correct answer is c, it even states so: explanation: when a vm is infected with ransomware, you should not restore the vm to the infected vm. this is because the ransomware will still be present on the vm, and it will encrypt the files again. you should also not restore the vm to any vm within the companys subscription. this is because the ransomware could spread to other vms in the subscription. the best way to restore a vm that is infected with ransomware is to restore it to a new azure vm. this will ensure that the ransomware is not present on the new vm.

R
Rajender
10/18/2023 3:54:00 AM

i would like to take psm1 exam.

B
Blessious Phiri
8/14/2023 9:53:00 AM

cbd and pdb are key to the database

A
Alkaed
10/19/2022 10:41:00 AM

the purchase and download process is very much streamlined. the xengine application is very nice and user-friendly but there is always room for improvement.

D
Dave Gregen
9/4/2023 3:17:00 PM

please upload p_sapea_2023

S
Sarah
6/13/2023 1:42:00 PM

anyone use this? the question dont seem to follow other formats and terminology i have been studying im getting worried

S
Shuv
10/3/2023 8:19:00 AM

good questions

R
Reb974
8/5/2023 1:44:00 AM

hello are these questions valid for ms-102

M
Mchal
7/20/2023 3:38:00 AM

some questions are wrongly answered but its good nonetheless

S
Sonbir
8/8/2023 1:04:00 PM

how to get system serial number using intune

M
Manju
10/19/2023 1:19:00 PM

is it really helpful to pass the exam

L
LeAnne Hair
8/24/2023 12:47:00 PM

#229 in incorrect - all the customers require an annual review

A
Abdul SK
9/28/2023 11:42:00 PM

kindy upload

A
Aderonke
10/23/2023 12:53:00 PM

fantastic assessment on psm 1

S
SAJI
7/20/2023 2:51:00 AM

56 question correct answer a,b

R
Raj Kumar
10/23/2023 8:52:00 PM

thank you for providing the q bank

P
piyush keshari
7/7/2023 9:46:00 PM

true quesstions

B
B.A.J
11/6/2023 7:01:00 AM

i can´t believe ms asks things like this, seems to be only marketing material.

G
Guss
5/23/2023 12:28:00 PM

hi, could you please add the last update of ns0-527

R
Rond65
8/22/2023 4:39:00 PM

question #3 refers to vnet4 and vnet5. however, there is no vnet5 listed in the case study (testlet 2).

C
Cheers
12/13/2023 9:55:00 AM

sometimes it may be good some times it may be

S
Sumita Bose
7/21/2023 1:01:00 AM

qs 4 answer seems wrong- please check

A
Amit
9/7/2023 12:53:00 AM

very detailed explanation !

F
FisherGirl
5/16/2022 10:36:00 PM

the interactive nature of the test engine application makes the preparation process less boring.

C
Chiranthaka
9/20/2023 11:15:00 AM

very useful.

AI Tutor 👋 I’m here to help!