During creation of a new Organization for All Applications in VCF Automation, which four NSX constructs are automatically configured at the regional networking step? (Choose four.)
Answer(s): A,B,E,G
Comprehensive and DetailedThe VCF Automation Networking Guide (9.0) documents that when an Organization for All Applications is created, networking constructs are provisioned automatically to provide immediate connectivity. Specifically, “During region creation, the system automatically deploys a Default VPC, a Provider Tier-0 Gateway, a VPC connectivity profile, and default SNAT rules to enable outbound access.” .DNAT rules are not provisioned by default (they must be configured for inbound services). Likewise, NSX Transit Gateway is a multi-region design element, not automatically deployed for a single org setup. A VDS is a vSphere construct and not part of the NSX automation performed at this stage. Therefore, the automatically created items are: Default VPC (A), Provider Tier-0 Gateway (B), SNAT rule (E), and VPC Connectivity Profile (G).
An administrator creates a custom alert in VCF Operations for a VM with a symptom definition: “Read Latency > 1 ms.” The alert should trigger immediately once the symptom condition occurs. What additional step is required to ensure the alert functions?
Answer(s): A
Comprehensive and DetailedThe VCF Operations 9.0 Monitoring Guide specifies: “For any alert definition to be active in the environment, it must be associated with and enabled in an Active Policy.” . Creating symptom and alert definitions only defines conditions; they do not generate alerts until policies include them. REST notification plugins or payload templates are used for outbound integrations, not for enabling alerts. A super metric is only needed for custom composite KPIs, not for native read latency which is a standard metric already available. Therefore, the required step is to enable the alert in an Active Policy so that when the symptom triggers (latency > 1 ms), the alert activates.
A large corporation recently experienced a power outage at one of its primary data centers resulting in service disruption for customers in that region. An administrator is tasked to assess the current infrastructure and propose a plan to improve resiliency.Current configuration:Single-site vSAN Express Storage Architecture (ESA) cluster12 hostsCluster resource utilization (CPU, memory, and storage) is under 30%Which solution would improve resiliency and minimize service disruption in data center outages with a recovery point objective (RPO) of zero without requiring additional hosts?
The VCF 9.0 Design Guide highlights that for resiliency across sites with RPO = 0, the recommended approach is a vSAN Stretched Cluster. Documentation states: “Stretched clusters provide site-level resilience by mirroring data across two fault domains (sites). In the event of a full site outage, workloads remain available with no data loss (RPO = 0).” Relocating six hosts to another site creates the two fault domains required for vSAN Stretched Cluster. Options B and C provide backup or redundancy but not synchronous replication with zero RPO. Option D (fault domains) protects against host/rack failures, not entire data center loss. Therefore, the correct solution is to relocate hosts and configure a stretched cluster.
An organization wants to enable Service and Application Discovery across their VMware Cloud Foundation (VCF) fleet. Which optional VMware Cloud Foundation (VCF) solution must the administrator enable or deploy to facilitate this capability?
Answer(s): D
The VCF Operations for Networks (formerly vRNI) enables Application Discovery and Network Visibility. According to VCF 9.0: “Operations for Networks provides flow-based application discovery, dependency mapping, and security planning. This allows administrators to visualize application topology and relationships across the VCF fleet.” By contrast, VCF Operations for Logs provides log aggregation, while the Collector provides integration for metrics, not discovery. The vSphere Supervisor enables Kubernetes workloads, not application discovery. Therefore, to achieve Service and Application Discovery, administrators must deploy VCF Operations for Networks.
An administrator is responsible for monitoring VMware vSAN performance across a VMware Cloud Foundation (VCF) instance. The administrator confirms VCF Operations is configured correctly. When viewing Storage Operations, the vSAN Cluster Performance widget is not displaying any dat a. What additional configuration should the administrator complete to ensure the widget displays data?
According to the VCF 9.0 Operations and vSAN Integration Guide, performance metrics in the vSAN Cluster Performance widget are only available when the vSAN Performance Service is enabled. The documentation states:“The vSAN Performance Service must be enabled in vCenter Server for each vSAN cluster to collect and visualize performance statistics in VCF Operations. Without this service, performance dashboards and widgets will not display data.”Option A (Support Insight) relates to telemetry with VMware, not performance widgets.Option B (Cloud proxy as Collector) is required for general collection but not specific to vSAN widget visibility.Option C (SMART data collection) provides disk health analytics, not cluster-level performance stats.Option D is correct, because enabling the vSAN Performance Service ensures that VCF Operations receives and displays data in the vSAN Performance dashboards.Therefore, the administrator must enable the vSAN Performance Service for all vSAN clusters in vCenter.
An administrator is tasked to configure network connectivity to the organization's corporate network for their container workloads to be deployed on VMware Kubernetes Service (VKS) clusters backed by VMware NSX networking on a new VMware Cloud Foundation (VCF) deployment. Which gateway connectivity type should the administrator deploy?
The VMware Cloud Foundation 9.0 networking design documentation specifies that container workloads running on VMware Kubernetes Service (VKS) with NSX networking require external connectivity via a Centralized Connectivity model. This is implemented using an NSX Tier-0 (T0) Gateway which provides north-south routing to the corporate physical network.The guide states: “In VKS deployments backed by NSX networking, workloads achieve external reachability through a centralized Tier-0 Gateway, ensuring integration with corporate networking and enterprise services.” This model ensures traffic consolidation, policy enforcement, and simplified routing for Kubernetes workloads.Round-robin Connectivity is not a supported NSX gateway connectivity model.Distributed Connectivity refers to east-west NSX overlay communication, not north-south connectivity.Physical Connectivity is not precise, as workloads do not connect directly to the physical network; instead, they use logical routing.Centralized Connectivity is the correct model, where the T0 Gateway centralizes external routing for container workloads.
VMware Cloud Foundation 9.0 – NSX Networking and VKS Deployment Guide (Tier-0 Gateway connectivity model)..
What is the purpose of Istio Service Mesh?
Answer(s): B
The VCF 9.0 Service Mesh Integration Guide defines Istio as: “Istio Service Mesh provides an infrastructure layer that transparently handles service-to-service communication, securing, observing, and controlling traffic between microservices.” The key purpose is enabling structured and observable communication between applications. While Istio includes discovery and load balancing, those are features, not the overarching purpose. A centralized routing table (Option D) is not the core definition. VMware documentation highlights Istio’s role in service-to-service communication, observability, and policy enforcement within the service mesh. Therefore, the correct answer is B.
An administrator is deciding on a storage solution to create the first management workload domain for a new VMware Cloud Foundation (VCF) instance. Which three storage solutions can be used as principal storage? (Choose three.)
Answer(s): C,D,E
The VCF 9.0 Architecture Guide outlines valid principal storage options for the management domain. It states: “The management domain must be deployed using vSAN, NFS, or Fibre Channel (FC). Supported protocols include NFSv3 and VMFS on FC.” vSAN (including OSA) is the default recommended option, but NFSv3 and VMFS on FC are also supported for environments where external storage arrays are required.NVMe/TCP and vVols are not supported for the initial management domain’s principal storage. vVols may be used in workload domains after deployment, but they are not a supported foundation for the management domain. Therefore, the three correct storage solutions for the first management workload domain are: VMFS on FC, NFSv3, and vSAN OSA.
Share your comments for VMware 2V0-17.25 exam with other users:
please share me the pdf..
q50: which two functions can be used by an end user when pivoting an interactive report? the correct answer is a, c because we do not have rank in the function pivoting you can check in the apex app
best to practice
so far it is good
please provide me the dump
i failed the cisa exam today. but i have found all the questions that were on the exam to be on this site.
in question 272 the right answer states that an autonomous acces point is "configured and managed by the wlc" but this is not what i have learned in my ccna course. is this a mistake? i understand that lightweight aps are managed by wlc while autonomous work as standalones on the wlan.
it was helpful
good question
really nice
please i need dumps for isc2 cybersecuity
ans is coldline i think
very helpful
can you please provide dumps so that it helps me more
thank you for providing me with the updated question and answers. this version has all the questions from the exam. i just saw them in my exam this morning. i passed my exam today.
how i can see exam questions?
can you please upload please?
question 75: option c is correct answer
please add this exam
please upoad
has anyone recently attended safe 6.0 certification? is it the samq question from here.
expository experience
52 should be b&c. controller failure has nothing to do with this type of issue. degraded state tells us its a raid issue, and if the os is missing then the bootable device isnt found. the only other consideration could be data loss but thats somewhat broad whereas b&c show understanding of the specific issues the question is asking about.
great help!!!
very useful tools
looks a good platform to prepare az-104
want to pass the exam
good resource
question 11 : d
only the free dumps will be enough for pass, or have to purchase the premium one. please suggest.
good questions. thanks.
good for practice.
great case study
the questions in this exam dumps is valid. i passed my test last monday. i only whish they had their pricing in inr instead of usd. but it is still worth it.
Keeping this site free takes real effort. We constantly battle automated scraping and unauthorized content copying. A quick account helps us protect the community and keep the site free.
To continue studying for your 2V0-17.25, please sign in or create a free account.