For several days, an administrator notices the following alerts:

· CVM NIC Speed Low Warning Alerts

· Warning Alerts of CVM NIC not performing at optimal speed

· CVM is disconnected from the network Critical Alert

· Network Visualization page shows excessive dropped packets on CVM/Host

Which steps should be taken to determine which problem should be addressed first?

  1. · Access the Hardware Page to verifyresources are available · Analyze ail CVM Speed Alerts in the Alerts/Events page · Analyze output for the network and interface properties and connectivity issues
  2. · Verify Host/CVM connectivity on the Network Visualization page · Use toverify the bridge and bond configuration · Review alerts/events page for the CVM disconnected error
  3. · Review Alerts page for NIC speed alerts and alert timing · Analyze the genesis.out log file for process failures · Assess the NIC properties inthe Network Visualization > Host Properties page D. · Restart networking services on the CVM
    · Determine the current configuration of the affected CVM via output · Access the Alerts/Events page for the CVM network connection failures

Answer(s): B

Explanation:

Ref:https://portal.nutanix.com/page/documents/kbs/details?targetId=kA00e000000CuaDCA S



A consultant is using the Foundation applet to create a cluster. During the process the consultant refreshes the progress bar web page and is concerned when nothing loads.

What should the consultant do to verify that Foundation has completed successfully?

  1. Return to the Foundation configuration page and start over.
  2. Update Java on the Foundation VM.
  3. Connect to any CVM IP address from a web browser.
  4. Restart the Foundation process.

Answer(s): C



After the migration, some SQL queries take longer to execute than prior to migration.

The following SQL best practices were applied while creating the SQL VM on Nutanix:

·8 vDisks per SQL server VM

·Database and Log files on separate vDisk

·2 TempDB database drives and 1 TempDB log drive

What should the administrator to do improve the SQL Server performance?

  1. Redistribute existing data by creating additional database file and enable autogrowth
  2. Create multiple TempDB data files and enable autogrowth
  3. Create multiple SQL log files and disable autogrowth
  4. Redistribute existing data by creating additional database files and disable autogrowth

Answer(s): A



After imaging the nodes and creating the cluster successfully, the consultant connects the cluster to the customer network. When logging into Prism, the events dashboard is full of errors.

What is causing the issue?

  1. The cluster was not stopped prior to connecting to the customer network.
  2. The Cluster Virtual IP Address (VIP) was not set up during the process.
  3. Foundation did not create the cluster successfully.
  4. The consultant did not run Nutanix Cluster Check (NCC..

Answer(s): A



After uploading a hypervisor ISO during the Foundation process, a consultant sees a message that the MD5 sum for the hypervisor is not found in the Whitelist file.

Which step should the consultant take next to resolve this issue?

  1. Download the hypervisor ISO again from the vendor website.
  2. Restart the Foundation process and upload the hypervisor again.
  3. Download the latest hypervisor ISO whitelist file from Nutanix portal.
  4. Check the hypervisor version in the Nutanix Compatibility Matrix.

Answer(s): C