Network Appliance NS0-527 Exam (page: 3)
Network Appliance NetApp Certified Implementation Engineer - Data Protection
Updated on: 25-Dec-2025

Viewing Page 3 of 33

Click the Exhibit button.



You must set up SVM replication for the first time using CLI. This replication will be used for DR purposes. The SVM configuration does not need to be replicated at this time. In this configuration, you will be reusing a default policy.

Referring to the exhibit, what are two missing steps from the SVM replication workflow? (Choose two.)

  1. Exclude specific LIFs and protocols from the replication policy.
  2. Create a relationship with the id-preserve option set to false.
  3. Initialize the newly created SnapMirror relationship.
  4. Initialize the relationship with the id-preserve option set to true.

Answer(s): B,D



Click the Exhibit button.

In an ONTAP environment, an SVM-DR relationship exists between your AFF A220 cluster and your FAS2720 cluster, with identity preserve enabled. You are asked to test the disaster recovery workflow in an upcoming maintenance window.

Referring to the exhibit, which step should be performed next to test the recovery workflow?

  1. Delete the SVM-DR relationship.
  2. Pause any ongoing transfers.
  3. Abort any ongoing transfers.
  4. Update any ongoing transfers.

Answer(s): C



Click the Exhibit button.

Referring to the exhibit, which three would be used to configure the three-way Data Center Disaster Recovery topology replication schedules? (Choose three.)

  1. Active IQ Unified Manager
  2. Active IQ
  3. ONTAP CLI
  4. ONTAP Select
  5. ONTAP System Manager

Answer(s): C,D,E


Reference:

http://197.253.9.244/ontap%209-5/Cluster%20Admin/2_Student%20Guide/STRSW-ILT- ONTAPADM_StudentGuide.pdf



You want to use a Fabric Pool to store destination SnapMirror data to an external capacity tier.
Which tiering policy would be used in this scenario?

  1. auto
  2. snapshot-only
  3. none
  4. backup

Answer(s): D


Reference:

https://community.netapp.com/t5/ONTAP-Discussions/FabricPool-tiering-Policy/td- p/138250



You must manually upgrade your company's 8-node cluster from ONTAP 9.5 to ONTAP 9.7. Due to the sensitivity of the data that is being stored on the cluster, it is company policy to perform these upgrades one node at a time.

What are two steps that you must perform to accomplish this task? (Choose two.)

  1. Terminate active NFS connections.
  2. Move Epsilon to maintain cluster quorum.
  3. Terminate active SMB connections.
  4. Change disk ownership.

Answer(s): B,C



Viewing Page 3 of 33



Share your comments for Network Appliance NS0-527 exam with other users:

Guss 5/23/2023 12:28:00 PM

hi, could you please add the last update of ns0-527
Anonymous


TTB 8/22/2023 5:30:00 AM

hi, could you please update the latest dump version
Anonymous