Network Appliance NetApp Certified Implementation Engineer - SAN, ONTAP NS0-521 Dumps in PDF

Free Network Appliance NS0-521 Real Questions (page: 9)

An administrator has a NetApp AFF cluster with two SVMs serving LUNs. SnapMirror active sync is configured, and a disaster recovery test is planned over the weekend.
Which NetApp ONTAP command will show the status of this test?

  1. snapmirror failover show
  2. network interface failover-groups show
  3. storage failover hwassist show
  4. snapnirror config-replication status show

Answer(s): A

Explanation:

To check the status of a SnapMirror active sync disaster recovery test on a NetApp ONTAP cluster, you would use the command snapmirror failover show. This command provides the necessary details about the failover status, helping administrators verify if the disaster recovery test is proceeding as expected. It displays the status of the failover groups and their readiness, which is essential for confirming the effectiveness of the disaster recovery setup. For more detailed information on SnapMirror commands and their usage, refer to:
NetApp Documentation - SnapMirror Commands(NetApp Community)(NetApp Community).



What configuration must be applied for NVMe/FC?

  1. Create multiple initiator zones and multiple target zones.
  2. Configure igroup and IQN mapping.
  3. Enable NPV on all fabric switches.
  4. Enable NPIV on all fabric switches.

Answer(s): D

Explanation:

When configuring NVMe/FC (NVMe over Fibre Channel), it is necessary to enable N_Port ID Virtualization (NPIV) on all fabric switches. NPIV allows multiple Fibre Channel initiators to share a single physical Fibre Channel port, which is crucial for NVMe/FC environments where efficient utilization of available ports is needed.
NPIV support enables the creation of virtual ports, which can significantly optimize the configuration and management of Fibre Channel fabrics, thus supporting NVMe/FC operations.
For further details, you can refer to:
NetApp Community - NVMe/FC Configuration(NetApp Community).
NetApp Documentation - NVMe Overview(NetApp).



A storage administrator has just completed an ISCSI implementation in a customer environment running VMware and needs to validate that the entire network path supports jumbo frames.
Which action should be taken?

  1. Ping from the host with fragmentation.
  2. Check the VMkernel adapter settings.
  3. Ping from the host without fragmentation.
  4. Check the broadcast domain settings.

Answer(s): A

Explanation:

To validate that the entire network path supports jumbo frames after an iSCSI implementation, you should perform a ping test from the host with fragmentation. This involves using the ping command with specific options to test jumbo frame support:

ping -M do -s 8972 <target_IP>
In this command:
-M do ensures the packets are not fragmented.
-s 8972 sets the packet size to 8972 bytes (9000 bytes MTU minus 28 bytes for the ICMP header). By confirming that the large packets are successfully transmitted without fragmentation, you can validate that the network path, including switches and adapters, supports jumbo frames.
For more details, you can check:
NetApp Documentation - iSCSI Configuration and Best Practices(NetApp)(NetApp).



An administrator installs a new NetApp ONTAP system in a customer's SAN environment. The customer wants to confirm that ALUA correctly changes the path states between Active/Optimized and Active/Nonoptimized.
Which event causes ALUA to change the path states?

  1. Shut down all FC LIFs on the HA partner node.
  2. Move the containing volume to the HA partner node.
  3. Shut down one FC LIF.
  4. Disconnect one FC cable on the node hosting the LUN.

Answer(s): A

Explanation:

ALUA (Asymmetric Logical Unit Access) is a protocol used in SAN environments to manage paths between a host and its storage. It enables the host to recognize and manage paths to the LUNs more efficiently by designating paths as either "Active/Optimized" or "Active/Nonoptimized". A significant event, such as shutting down all FC LIFs on the HA partner node, will trigger ALUA to change the path states. This action effectively causes the storage paths to transition from the HA partner node to the local node, switching the path states from Active/Nonoptimized to Active/Optimized on the paths that remain active.
For more information, you can refer to:
NetApp Community Discussion on ALUA
NetApp Documentation on ALUA



An engineer Is implementing a data migration scenario for a customer who has multiple FC LUNs across multiple third-party SAN arrays. The engineer wants to use Foreign LUN Import (FLI) for the migration.
What is a requirement on the destination NetApp ONTAP cluster for FLI?

  1. A valid SnapMirror license
  2. At least one FC port in initiator mode
  3. A valid NetApp XCP license
  4. At least one FC port in target mode

Answer(s): D

Explanation:

When using Foreign LUN Import (FLI) for migrating LUNs from third-party SAN arrays to a NetApp ONTAP system, one of the requirements is to have at least one Fibre Channel (FC) port configured in target mode on the destination NetApp ONTAP cluster. This configuration is necessary to facilitate the migration process as the target mode port will accept and manage incoming data from the source SAN arrays.
For additional details, refer to:
NetApp Documentation on FLI



Share your comments for Network Appliance NS0-521 exam with other users:

C
Christian Klein
6/23/2023 1:32:00 PM

is it legit questions from sap certifications ?

A
anonymous
1/12/2024 3:34:00 PM

question 16 should be b (changing the connector settings on the monitor) pc and monitor were powered on. the lights on the pc are on indicating power. the monitor is showing an error text indicating that it is receiving power too. this is a clear sign of having the wrong input selected on the monitor. thus, the "connector setting" needs to be switched from hdmi to display port on the monitor so it receives the signal from the pc, or the other way around (display port to hdmi).

N
NSPK
1/18/2024 10:26:00 AM

q 10. ans is d (in the target org: open deployment settings, click edit next to the source org. select allow inbound changes and save

M
mohamed abdo
9/1/2023 4:59:00 AM

very useful

T
Tom
3/18/2022 8:00:00 PM

i purchased this exam dumps from another website with way more questions but they were all invalid and outdate. this exam dumps was right to the point and all from recent exam. it was a hard pass.

E
Edrick GOP
10/24/2023 6:00:00 AM

it was a good experience and i got 90% in the 200-901 exam.

A
anonymous
8/10/2023 2:28:00 AM

hi please upload this

B
Bakir
7/6/2023 7:24:00 AM

please upload it

A
Aman
6/18/2023 1:27:00 PM

really need this dump. can you please help.

N
Neela Para
1/8/2024 6:39:00 PM

really good and covers many areas explaining the answer.

K
Karan Patel
8/15/2023 12:51:00 AM

yes, can you please upload the exam?

N
NISHAD
11/7/2023 11:28:00 AM

how many questions are there in these dumps?

P
Pankaj
7/3/2023 3:57:00 AM

hi team, please upload this , i need it.

D
DN
9/4/2023 11:19:00 PM

question 14 - run terraform import: this is the recommended best practice for bringing manually created or destroyed resources under terraform management. you use terraform import to associate an existing resource with a terraform resource configuration. this ensures that terraform is aware of the resource, and you can subsequently manage it with terraform.

Z
Zhiguang
8/19/2023 11:37:00 PM

please upload dump. thanks in advance.

D
deedee
12/23/2023 5:51:00 PM

great great

A
Asad Khan
11/1/2023 3:10:00 AM

answer 16 should be b your organizational policies require you to use virtual machines directly

S
Sale Danasabe
10/24/2023 5:21:00 PM

the question are kind of tricky of you didnt get the hnag on it.

L
Luis
11/16/2023 1:39:00 PM

can anyone tell me if this is for rhel8 or rhel9?

H
hik
1/19/2024 1:47:00 PM

good content

B
Blessious Phiri
8/15/2023 2:18:00 PM

pdb and cdb are critical to the database

Z
Zuned
10/22/2023 4:39:00 AM

till 104 questions are free, lets see how it helps me in my exam today.

M
Muhammad Rawish Siddiqui
12/3/2023 12:11:00 PM

question # 56, answer is true not false.

A
Amaresh Vashishtha
8/27/2023 1:33:00 AM

i would be requiring dumps to prepare for certification exam

A
Asad
9/8/2023 1:01:00 AM

very helpful

B
Blessious Phiri
8/13/2023 3:10:00 PM

control file is the heart of rman backup

S
Senthil
9/19/2023 5:47:00 AM

hi could you please upload the ibm c2090-543 dumps

H
Harry
6/27/2023 7:20:00 AM

appriciate if you could upload this again

A
Anonymous
7/10/2023 4:10:00 AM

please upload the dump

R
Raja
6/20/2023 5:30:00 AM

i found some questions answers mismatch with explanation answers. please properly update

D
Doora
11/30/2023 4:20:00 AM

nothing to mention

D
deally
1/19/2024 3:41:00 PM

knowable questions

S
Sonia
7/23/2023 4:03:00 PM

very helpfull

B
binEY
10/6/2023 5:15:00 AM

good questions

AI Tutor 👋 I’m here to help!