An administrator has a NetApp AFF cluster with two SVMs serving LUNs. SnapMirror active sync is configured, and a disaster recovery test is planned over the weekend.
Which NetApp ONTAP command will show the status of this test?

  1. snapmirror failover show
  2. network interface failover-groups show
  3. storage failover hwassist show
  4. snapnirror config-replication status show

Answer(s): A

Explanation:

To check the status of a SnapMirror active sync disaster recovery test on a NetApp ONTAP cluster, you would use the command snapmirror failover show. This command provides the necessary details about the failover status, helping administrators verify if the disaster recovery test is proceeding as expected. It displays the status of the failover groups and their readiness, which is essential for confirming the effectiveness of the disaster recovery setup. For more detailed information on SnapMirror commands and their usage, refer to:
NetApp Documentation - SnapMirror Commands(NetApp Community)(NetApp Community).



What configuration must be applied for NVMe/FC?

  1. Create multiple initiator zones and multiple target zones.
  2. Configure igroup and IQN mapping.
  3. Enable NPV on all fabric switches.
  4. Enable NPIV on all fabric switches.

Answer(s): D

Explanation:

When configuring NVMe/FC (NVMe over Fibre Channel), it is necessary to enable N_Port ID Virtualization (NPIV) on all fabric switches. NPIV allows multiple Fibre Channel initiators to share a single physical Fibre Channel port, which is crucial for NVMe/FC environments where efficient utilization of available ports is needed.
NPIV support enables the creation of virtual ports, which can significantly optimize the configuration and management of Fibre Channel fabrics, thus supporting NVMe/FC operations.
For further details, you can refer to:
NetApp Community - NVMe/FC Configuration(NetApp Community).
NetApp Documentation - NVMe Overview(NetApp).



A storage administrator has just completed an ISCSI implementation in a customer environment running VMware and needs to validate that the entire network path supports jumbo frames.
Which action should be taken?

  1. Ping from the host with fragmentation.
  2. Check the VMkernel adapter settings.
  3. Ping from the host without fragmentation.
  4. Check the broadcast domain settings.

Answer(s): A

Explanation:

To validate that the entire network path supports jumbo frames after an iSCSI implementation, you should perform a ping test from the host with fragmentation. This involves using the ping command with specific options to test jumbo frame support:

ping -M do -s 8972 <target_IP>
In this command:
-M do ensures the packets are not fragmented.
-s 8972 sets the packet size to 8972 bytes (9000 bytes MTU minus 28 bytes for the ICMP header). By confirming that the large packets are successfully transmitted without fragmentation, you can validate that the network path, including switches and adapters, supports jumbo frames.
For more details, you can check:
NetApp Documentation - iSCSI Configuration and Best Practices(NetApp)(NetApp).



An administrator installs a new NetApp ONTAP system in a customer's SAN environment. The customer wants to confirm that ALUA correctly changes the path states between Active/Optimized and Active/Nonoptimized.
Which event causes ALUA to change the path states?

  1. Shut down all FC LIFs on the HA partner node.
  2. Move the containing volume to the HA partner node.
  3. Shut down one FC LIF.
  4. Disconnect one FC cable on the node hosting the LUN.

Answer(s): A

Explanation:

ALUA (Asymmetric Logical Unit Access) is a protocol used in SAN environments to manage paths between a host and its storage. It enables the host to recognize and manage paths to the LUNs more efficiently by designating paths as either "Active/Optimized" or "Active/Nonoptimized". A significant event, such as shutting down all FC LIFs on the HA partner node, will trigger ALUA to change the path states. This action effectively causes the storage paths to transition from the HA partner node to the local node, switching the path states from Active/Nonoptimized to Active/Optimized on the paths that remain active.
For more information, you can refer to:
NetApp Community Discussion on ALUA
NetApp Documentation on ALUA



An engineer Is implementing a data migration scenario for a customer who has multiple FC LUNs across multiple third-party SAN arrays. The engineer wants to use Foreign LUN Import (FLI) for the migration.
What is a requirement on the destination NetApp ONTAP cluster for FLI?

  1. A valid SnapMirror license
  2. At least one FC port in initiator mode
  3. A valid NetApp XCP license
  4. At least one FC port in target mode

Answer(s): D

Explanation:

When using Foreign LUN Import (FLI) for migrating LUNs from third-party SAN arrays to a NetApp ONTAP system, one of the requirements is to have at least one Fibre Channel (FC) port configured in target mode on the destination NetApp ONTAP cluster. This configuration is necessary to facilitate the migration process as the target mode port will accept and manage incoming data from the source SAN arrays.
For additional details, refer to:
NetApp Documentation on FLI



Share your comments for Network Appliance NS0-521 exam with other users:

F
Faritha
8/10/2023 6:00:00 PM

for question 4, the righr answer is :recover automatically from failures

A
Anonymous
9/14/2023 4:27:00 AM

question number 4s answer is 3, option c. i

P
p das
12/7/2023 11:41:00 PM

very good questions

A
Anna
1/5/2024 1:12:00 AM

i am confused about the answers to the questions. are the answers correct?

B
Bhavya
9/13/2023 10:15:00 AM

very usefull

R
Rahul Kumar
8/31/2023 12:30:00 PM

need certification.

D
Diran Ole
9/17/2023 5:15:00 PM

great exam prep

V
Venkata Subbarao Bandaru
6/24/2023 8:45:00 AM

i require dump

D
D
7/15/2023 1:38:00 AM

good morning, could you please upload this exam again,

A
Ann
9/15/2023 5:39:00 PM

hi can you please upload the dumps for sap contingent module. thanks

S
Sridhar
1/16/2024 9:19:00 PM

good questions

S
Summer
10/4/2023 9:57:00 PM

looking forward to the real exam

V
vv
12/2/2023 2:45:00 PM

good ones for exam preparation

D
Danny Zas
9/15/2023 4:45:00 AM

this is a good experience

S
SM 1211
10/12/2023 10:06:00 PM

hi everyone

A
A
10/2/2023 6:08:00 PM

waiting for the dump. please upload.

A
Anonymous
7/16/2023 11:05:00 AM

upload cks exam questions

J
Johan
12/13/2023 8:16:00 AM

awesome training material

P
PC
7/28/2023 3:49:00 PM

where is dump

Y
YoloStar Yoloing
10/22/2023 9:58:00 PM

q. 289 - the correct answer should be b not d, since the question asks for the most secure way to provide access to a s3 bucket (a single one), and by principle of the least privilege you should not be giving access to all buckets.

Z
Zelalem Nega
5/14/2023 12:45:00 PM

please i need if possible h12-831,

U
unknown-R
11/23/2023 7:36:00 AM

good collection of questions and solution for pl500 certification

S
Swaminathan
5/11/2023 9:59:00 AM

i would like to appear the exam.

V
Veenu
10/24/2023 6:26:00 AM

i am very happy as i cleared my comptia a+ 220-1101 exam. i studied from as it has all exam dumps and mock tests available. i got 91% on the test.

K
Karan
5/17/2023 4:26:00 AM

need this dump

R
Ramesh Kutumbaka
12/30/2023 11:17:00 PM

its really good to eventuate knowledge before appearing for the actual exam.

A
anonymous
7/20/2023 10:31:00 PM

this is great

X
Xenofon
6/26/2023 9:35:00 AM

please i want the questions to pass the exam

D
Diego
1/21/2024 8:21:00 PM

i need to pass exam

V
Vichhai
12/25/2023 3:25:00 AM

great, i appreciate it.

P
P Simon
8/25/2023 2:39:00 AM

please could you upload (isc)2 certified in cybersecurity (cc) exam questions

K
Karim
10/8/2023 8:34:00 PM

good questions, wrong answers

I
Itumeleng
1/6/2024 12:53:00 PM

im preparing for exams

M
MS
1/19/2024 2:56:00 PM

question no: 42 isnt azure vm an iaas solution? so, shouldnt the answer be "no"?

AI Tutor 👋 I’m here to help!