Refer to the exhibit.


Based on the configuration, what would happen if this FortiWeb were to Io se power? (Choose two.)

  1. Traffic that passes between port5 and port6 will be inspected.
  2. Traffic will be interrupted between port3 and port4.
  3. All traffic will be interrupted.
  4. Traffic will pass between port5 and port6 uninspected.

Answer(s): B,D



Refer to the exhibit:


FortiWeb is configured to block traffic from Japan to your web application server. However, in the log s, the administrator is seeing traffic allowed from one particular IP address which is geo-located in Japan. What can the administrator do to solve this problem? (Choose two.)

  1. Manually update the geo-location IP addresses for Japan.
  2. If the IP address is configured as a geo reputation exception, remove it.
  3. Configure the IP address as a blacklisted IP address.
  4. If the IP address is configured as an IP reputation exception, remove it.

Answer(s): A,C

Explanation:

IP reputation leverages m any techniques for accurate, early, and frequently updated identification of compromised and malicious clients so you can block attackers before they target your servers.
IP blacklisting is a method used to filter out illegitimate or malicious IP addresses from accessing your networks. Blacklists are lists c obtaining ranges of or individual IP addresses that you want to block.



Which algorithm is used to build mathematical models for bot detection?

  1. HCM
  2. SVN
  3. SVM
  4. HMM

Answer(s): C

Explanation:

FortiWeb uses SVM (Support Vector Machine) algorithm to build up the bot detection model



A client is trying to start a session from a page that would normally be accessible only after the client has logged in. When a start page rule detects the invalid session access, what can FortiWeb do? (Choose three.)

  1. Display an access policy message, then allow the client to continue
  2. Redirect the client to the login page
  3. Allow the page access, but log the violation
  4. Prompt the client to authenticate
  5. Reply with a 403 Forbidden HTTP error

Answer(s): B,C,E



Refer to the exhibit.


Many legitimate users are being identified as bots. FortiWeb bot detection has been configured with the settings shown in the exhibit. The FortiWeb administrator has already verified that the current model is accurate. What can the administrator do to fix this problem, making sure that real bots are not allowed through FortiWeb?

  1. Change Model Type to Strict
  2. Change Action under Action Settings to Alert
  3. Dis able Dynamically Update Model
  4. Enable Bot Confirmation

Answer(s): D

Explanation:

Bot Confirmation
If the number of anomalies from a user has reached the Anomaly Count, the system executes Bot Confirmation before taking actions.
The Bot Confirmation is to confirm if the user is indeed a bot. The system sends RBE (Real Browser Enforcement) JavaScript or CAPTCHA to the client to double check if it’s a real bot.



Share your comments for Fortinet NSE6_FWB-6.1 exam with other users:

P
Puneeth
10/5/2023 2:06:00 AM

new to this site but i feel it is good

A
Ashok Kumar
1/2/2024 6:53:00 AM

the correct answer to q8 is b. explanation since the mule app has a dependency, it is necessary to include project modules and dependencies to make sure the app will run successfully on the runtime on any other machine. source code of the component that the mule app is dependent of does not need to be included in the exported jar file, because the source code is not being used while executing an app. compiled code is being used instead.

M
Merry
7/30/2023 6:57:00 AM

good questions

V
VoiceofMidnight
12/17/2023 4:07:00 PM

Delayed the exam until December 29th.

U
Umar Ali
8/29/2023 2:59:00 PM

A and D are True

V
vel
8/28/2023 9:17:09 AM

good one with explanation

G
Gurdeep
1/18/2024 4:00:15 PM

This is one of the most useful study guides I have ever used.

AI Tutor 👋 I’m here to help!