EXIN CDCP Exam (page: 2)
EXIN Certified Data Centre Professional
Updated on: 12-Feb-2026

Viewing Page 2 of 16

Which one of the following is a factor that can affect Availability and Reliability?

  1. Inadequate Cooling
  2. Employee Salaries
  3. Radio Active Waves
  4. Attenuation

Answer(s): A

Explanation:

Availability and reliability are two important aspects of data centre performance that measure how often the system is operational and how dependable it is. According to the EPI Data Centre

Framework, availability is the percentage of time that a system or component is in an operable state, while reliability is the probability that a system or component will perform its required function under given conditions for a specified period of time. Both availability and reliability can be affected by various factors, such as design, maintenance, human error, power supply, security, etc. One of the factors that can have a significant impact on both availability and reliability is cooling. Cooling is essential for maintaining the optimal temperature and humidity levels for the IT equipment and preventing overheating, which can cause failures, downtime, and reduced lifespan. Inadequate cooling can result from insufficient capacity, poor airflow management, faulty components, or environmental conditions. Inadequate cooling can reduce the availability and reliability of the data centre by increasing the risk of thermal stress, hot spots, performance degradation, and equipment damage. Therefore, cooling is a critical factor that can affect availability and reliability in a data centre.


Reference:

· EPI Data Centre Framework1
· EPI Data Centre Training Framework2
· EPI Data Centre Competence Framework3
· Data Center Availability, Reliability Hinge On Numerous Factors4 · A Look at Data Center Reliability and Availability5



Which type of Fire Detection Device is recommended for protecting a Data Center?

  1. Heat detector
  2. Smoke detector
  3. Flame detector
  4. None of the above

Answer(s): B

Explanation:

According to the CDCP® Preparation Guide, smoke detectors are the most common type of fire detection devices used in data centers, as they can detect a fire in its early stages and provide early warning to the occupants and authorities. Smoke detectors can be either spot-type or air-aspirating, depending on the design and goals of the data center. Spot-type detectors are inexpensive and simple, but may cause activation delay and false alarms. Air-aspirating detectors are more sensitive and reliable, but may require more maintenance and installation costs. Both types of detectors should be installed in accordance with the relevant standards and codes, such as NFPA 72 and EN 54.


Reference:

CDCP® Preparation Guide, page 30-31. Evaluating Fire Detection Options For Data Centers. Fire Detection and Suppression Systems in a Data Center.



The expected time to Recover/Repair from a system from a failure is defined as .

  1. MTBF
  2. MCBF
  3. MLBF
  4. MTTR

Answer(s): D

Explanation:

The expected time to recover or repair from a system from a failure is defined as MTTR (mean time to recovery or mean time to repair). MTTR is the average time it takes to restore a system or product to its normal operation after a failure. MTTR includes the time spent on detecting, diagnosing, and fixing the problem. MTTR is an important metric for measuring the reliability and availability of a system or product, as well as the efficiency and effectiveness of the incident management process. A lower MTTR indicates a faster and more reliable recovery or repair process.


Reference:

· EPI Data Centre Professional (CDCP®) Preparation Guide, page 17 · What is MTTR? | IBM
· Explained: All Meanings of MTTR and Other Incident Metrics



Which type of Humidifier suspends quartz lamps over an open pool of water?

  1. Infrared Humidifiers
  2. Water Canister Humidifier
  3. Steam Canister Humidifier
  4. Ultrasonic Humidifier

Answer(s): A

Explanation:

Infrared humidifiers are a type of humidifier that use quartz lamps to heat water in an open pool and evaporate it into the air. They are energy-intensive and require frequent maintenance and cleaning. They are not recommended for data centers, as they can introduce contaminants and bacteria into the air, and increase the risk of fire and electrical hazards.


Reference:

EPI Data Centre Training Framework, CDCP Preparation Guide, Make Humidification Adjustments | ENERGY STAR



Which one of the following is a core objective of a Business Value in an organization?

  1. Reducing Costs
  2. Reducing the Deficit
  3. Increasing Sales
  4. None of the above

Answer(s): D

Explanation:

According to the EPI Data Centre Professional (CDCP®) Reference Materials, a core objective of a Business Value in an organization is to create value for customers and stakeholders1. This means delivering products or services that meet or exceed customer expectations, while also generating profits or benefits for the organization and its shareholders. Reducing costs, reducing the deficit, and increasing sales are possible ways to achieve this objective, but they are not the core objective itself.


Reference:

1: EPI Data Centre Professional (CDCP®) Reference Materials, page 9.



Viewing Page 2 of 16



Share your comments for EXIN CDCP exam with other users:

Ben 9/9/2023 7:35:00 AM

please upload it
Anonymous


anonymous 9/20/2023 11:27:00 PM

hye when will post again the past year question for this h13-311_v3 part since i have to for my test tommorow…thank you very much
Anonymous


Randall 9/28/2023 8:25:00 PM

on question 22, option b-once per session is also valid.
Anonymous


Tshegofatso 8/28/2023 11:51:00 AM

this website is very helpful
SOUTH AFRICA


philly 9/18/2023 2:40:00 PM

its my first time exam
SOUTH AFRICA


Beexam 9/4/2023 9:06:00 PM

correct answers are device configuration-enable the automatic installation of webview2 runtime. & policy management- prevent users from submitting feedback.
NEW ZEALAND


RAWI 7/9/2023 4:54:00 AM

is this dump still valid? today is 9-july-2023
SWEDEN


Annie 6/7/2023 3:46:00 AM

i need this exam.. please upload these are really helpful
PAKISTAN


Shubhra Rathi 8/26/2023 1:08:00 PM

please upload the oracle 1z0-1059-22 dumps
Anonymous


Shiji 10/15/2023 1:34:00 PM

very good questions
INDIA


Rita Rony 11/27/2023 1:36:00 PM

nice, first step to exams
Anonymous


Aloke Paul 9/11/2023 6:53:00 AM

is this valid for chfiv9 as well... as i am reker 3rd time...
CHINA


Calbert Francis 1/15/2024 8:19:00 PM

great exam for people taking 220-1101
UNITED STATES


Ayushi Baria 11/7/2023 7:44:00 AM

this is very helpfull for me
Anonymous


alma 8/25/2023 1:20:00 PM

just started preparing for the exam
UNITED KINGDOM


CW 7/10/2023 6:46:00 PM

these are the type of questions i need.
UNITED STATES


Nobody 8/30/2023 9:54:00 PM

does this actually work? are they the exam questions and answers word for word?
Anonymous


Salah 7/23/2023 9:46:00 AM

thanks for providing these questions
Anonymous


Ritu 9/15/2023 5:55:00 AM

interesting
CANADA


Ron 5/30/2023 8:33:00 AM

these dumps are pretty good.
Anonymous


Sowl 8/10/2023 6:22:00 PM

good questions
UNITED STATES


Blessious Phiri 8/15/2023 2:02:00 PM

dbua is used for upgrading oracle database
Anonymous


Richard 10/24/2023 6:12:00 AM

i am thrilled to say that i passed my amazon web services mls-c01 exam, thanks to study materials. they were comprehensive and well-structured, making my preparation efficient.
Anonymous


Janjua 5/22/2023 3:31:00 PM

please upload latest ibm ace c1000-056 dumps
GERMANY


Matt 12/30/2023 11:18:00 AM

if only explanations were provided...
FRANCE


Rasha 6/29/2023 8:23:00 PM

yes .. i need the dump if you can help me
Anonymous


Anonymous 7/25/2023 8:05:00 AM

good morning, could you please upload this exam again?
SPAIN


AJ 9/24/2023 9:32:00 AM

hi please upload sre foundation and practitioner exam questions
Anonymous


peter parker 8/10/2023 10:59:00 AM

the exam is listed as 80 questions with a pass mark of 70%, how is your 50 questions related?
Anonymous


Berihun 7/13/2023 7:29:00 AM

all questions are so important and covers all ccna modules
Anonymous


nspk 1/19/2024 12:53:00 AM

q 44. ans:- b (goto setup > order settings > select enable optional price books for orders) reference link --> https://resources.docs.salesforce.com/latest/latest/en-us/sfdc/pdf/sfom_impl_b2b_b2b2c.pdf(decide whether you want to enable the optional price books feature. if so, select enable optional price books for orders. you can use orders in salesforce while managing price books in an external platform. if you’re using d2c commerce, you must select enable optional price books for orders.)
Anonymous


Muhammad Rawish Siddiqui 12/2/2023 5:28:00 AM

"cost of replacing data if it were lost" is also correct.
SAUDI ARABIA


Anonymous 7/14/2023 3:17:00 AM

pls upload the questions
UNITED STATES


Mukesh 7/10/2023 4:14:00 PM

good questions
UNITED KINGDOM