Oracle 1Z0-1091-22 Exam (page: 1)
Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional
Updated on: 28-Sep-2025

Viewing Page 1 of 12

A business needs a new Service Order process that includes meter commands.
Which THREE options should you configure to build this process?

  1. Measuring component type
  2. Device configuration type
  3. Activity type
  4. Communication type Message sender

Answer(s): A,C,D

Explanation:

To build a new Service Order process that includes meter commands, you need to configure the following options:
Measuring component type: This defines the type of measurement that a device can record, such as scalar, interval, or event. You can associate meter commands with measuring component types to perform actions on devices that have those types.
Activity type: This defines the type of work that needs to be performed on a service point or device, such as installation, removal, or inspection. You can associate meter commands with activity types to trigger actions on devices when an activity is completed. Communication type Message sender: This defines the communication channel and protocol that is used to send meter commands to devices. You can configure message senders for different communication types, such as AMI, AMR, or manual.
You do not need to configure device configuration type, which defines the physical characteristics and attributes of a device, such as manufacturer, model, or serial number. Device configuration type does not affect meter commands.


Reference:

1: Oracle Utilities Meter Solution Cloud Service - Business User Guide - Chapter 4:
Configuring Meter Solution Cloud Service



In the SaaS solution, how should you configure equipment that attaches to an asset, such as a communication module attached to a meter?

  1. Set up a component
  2. Create a master child asset
  3. Add a sub-asset
  4. Add a constituent part

Answer(s): A

Explanation:

To configure equipment that attaches to an asset, such as a communication module attached to a meter, you should set up a component. A component is a part of an asset that can be installed and removed independently of the asset. You can define component types and associate them with asset types. For example, you can define a communication module component type and associate it with a meter asset type.
You do not need to create a master child asset, which is a relationship between two assets that are installed at different service points but are functionally related. For example, you can define a transformer as a master asset and a meter as a child asset. A master child asset is not suitable for equipment that attaches to an asset.
You do not need to add a sub-asset, which is an asset that is installed at the same service point as another asset but has its own measuring components and usage subscriptions. For example, you can define a meter as a sub-asset of another meter if they share the same service point but have different measurements. A sub-asset is not suitable for equipment that attaches to an asset. You do not need to add a constituent part, which is an attribute of an asset that cannot be installed or removed independently of the asset. For example, you can define a battery as a constituent part of a meter if it is embedded in the meter and cannot be replaced. A constituent part is not suitable for equipment that attaches to an asset.


Reference:

2: Oracle Utilities Meter Solution Cloud Service - Business User Guide - Chapter 5:
Managing Assets



3. For a Meter Data Management (MDM) implementation, customer information system (CIS) requires the following bill determinants:
· For scalar meters, scalar consumption values will be sent to CIS. · For interval meters, billed on time-of-use (TOU) rates, consumption values will be provided based on the specific TOU periods, for example: on-peak, off-peak, and shoulder. Based on these requirements, which TWO usage subscription or usage calculation group configuration options should you set up to allow an implementation to send bill determinants to CIS?

  1. Scalar specific group as a fallback Validation, Estimation, and Editing (VEE) group.
  2. TOU usage group as a fallback VEE group.
  3. Scalar usage calculation rule with a valid usage group.
  4. TOU usage rule with a valid usage group.

Answer(s): C

Explanation:

To allow an implementation to send bill determinants to CIS based on the requirements, you should set up the following usage subscription or usage calculation group configuration options:
Scalar usage calculation rule with a valid usage group: This defines how scalar consumption values are calculated from measurements and sent to CIS. You can define scalar usage calculation rules for different measurement types and associate them with usage groups. A usage group is a collection of usage calculation rules that are applied to measurements based on certain criteria. TOU usage rule with a valid usage group: This defines how TOU consumption values are calculated from measurements and sent to CIS based on specific TOU periods. You can define TOU usage rules for different measurement types and associate them with usage groups. A usage group is a collection of usage calculation rules that are applied to measurements based on certain criteria. You do not need to set up scalar specific group as a fallback VEE group or TOU usage group as a fallback VEE group. A fallback VEE group is used when there is no matching VEE group for a measurement based on its characteristics. A VEE group is a collection of VEE rules that are applied to measurements to validate, estimate, and edit them



A customer is starting an Advanced Meter Infrastructure (AMI) roll-out initiative and plans to use Meter Data Management (MDM). The AMI meters will record the consumption reading every 15 minutes through the day and a single register read at the end of the day. They plan to use this data for billing, load research, and presentment via their customer web portal.
What is the minimum number of measuring component types the customer needs to create in MDM?

  1. A single measuring component type to store AMI data (15-minute interval reading along with the daily scalar register reading) for each case purpose, far example: billing, load research, and customer web portal.
  2. A single measuring component type to store the 15-minute interval readings and another measuring component type for the daily scalar register reading.
  3. A single measuring component type to store the 15-minute interval readings, and another measuring component type for the daily scalar register reading for each use case purpose, for example: billing, load research, and customer web portal.
  4. A single measuring component type to store the 15-minute interval readings along with the daily scalar register reading.

Answer(s): D

Explanation:

The customer needs to create a single measuring component type to store the 15-minute interval readings along with the daily scalar register reading. A measuring component type defines the type of measurement that a device can record, such as scalar, interval, or event. A measuring component type can store multiple measurement types, such as interval and scalar, for different purposes, such as billing, load research, and presentment.
The customer does not need to create separate measuring component types for each measurement type or each use case purpose. This would result in unnecessary duplication of data and complexity of configuration.


Reference:

1: Oracle Utilities Meter Data Management - Business User Guide - Chapter 3: Configuring Meter Data Management



What are the THREE uses of the Smart Grid Gateway (SGG)?

  1. Sharing event information with downstream systems
  2. Sharing customer information
  3. Connecting to Smart Meter systems
  4. Communicating directly with meters
  5. Sharing outage information with outage management systems

Answer(s): A,C,E

Explanation:

The Smart Grid Gateway (SGG) is a middleware component that provides integration between Oracle Utilities Meter Data Management and smart meter systems. The SGG has three main uses:
Sharing event information with downstream systems: The SGG can process events from smart meter systems and send them to downstream systems, such as customer information systems (CIS), outage management systems (OMS), or distribution management systems (DMS). Events are occurrences that happen on devices or networks, such as tampering, low battery, or power outage. Connecting to Smart Meter systems: The SGG can communicate with smart meter systems using various protocols and adapters. The SGG can support multiple smart meter systems simultaneously and provide a common interface for Oracle Utilities Meter Data Management. Sharing outage information with outage management systems: The SGG can process outage events from smart meter systems and send them to outage management systems for analysis and restoration. Outage events are events that indicate a loss or restoration of power on a device or network.
The SGG does not share customer information or communicate directly with meters. Customer information is managed by Oracle Utilities Customer Cloud Service or Oracle Utilities Customer Care and Billing. Communication with meters is handled by smart meter systems that connect to the SGG.


Reference:

Oracle Utilities Meter Data Management - Business User Guide - Chapter 8: Using Smart Grid Gateway



Viewing Page 1 of 12



Share your comments for Oracle 1Z0-1091-22 exam with other users:

sarra 1/17/2024 3:44:00 AM

the aaa triad in information security is authentication, accounting and authorisation so the answer should be d 1, 3 and 5.
UNITED KINGDOM


DBS 5/14/2023 12:56:00 PM

need to attend this
UNITED STATES


Da_costa 8/1/2023 5:28:00 PM

these are free brain dumps i understand, how can one get free pdf
Anonymous


vikas 10/28/2023 6:57:00 AM

provide access
EUROPEAN UNION


Abdullah 9/29/2023 2:06:00 AM

good morning
Anonymous


Raj 6/26/2023 3:12:00 PM

please upload the ncp-mci 6.5 dumps, really need to practice this one. thanks guys
Anonymous


Miguel 10/5/2023 12:21:00 PM

question 16: https://help.salesforce.com/s/articleview?id=sf.care_console_overview.htm&type=5
SPAIN


Hiren Ladva 7/8/2023 10:34:00 PM

yes i m prepared exam
Anonymous


oliverjames 10/24/2023 5:37:00 AM

my experience was great with this site as i studied for the ms-900 from here and got 900/1000 on the test. my main focus was on the tutorials which were provided and practice questions. thanks!
GERMANY


Bhuddhiman 7/20/2023 11:52:00 AM

great course
UNITED STATES


Anuj 1/14/2024 4:07:00 PM

very good question
Anonymous


Saravana Kumar TS 12/8/2023 9:49:00 AM

question: 93 which statement is true regarding the result? sales contain 6 columns and values contain 7 columns so c is not right answer.
INDIA


Lue 3/30/2023 11:43:00 PM

highly recommend just passed my exam.
CANADA


DC 1/7/2024 10:17:00 AM

great practice! thanks
UNITED STATES


Anonymus 11/9/2023 5:41:00 AM

anyone who wrote this exam recently?
SOUTH AFRICA


Khalid Javid 11/17/2023 3:46:00 PM

kindly share the dump
Anonymous


Na 8/9/2023 8:39:00 AM

could you please upload cfe fraud prevention and deterrence questions? it will be very much helpful.
Anonymous


shime 10/23/2023 10:03:00 AM

this is really very very helpful for mcd level 1
ETHIOPIA


Vnu 6/3/2023 2:39:00 AM

very helpful!
Anonymous


Steve 8/17/2023 2:19:00 PM

question #18s answer should be a, not d. this should be corrected. it should be minvalidityperiod
CANADA


RITEISH 12/24/2023 4:33:00 AM

thanks for the exact solution
Anonymous


SB 10/15/2023 7:58:00 AM

need to refer the questions and have to give the exam
INDIA


Mike Derfalem 7/16/2023 7:59:00 PM

i need it right now if it was possible please
Anonymous


Isak 7/6/2023 3:21:00 AM

i need it very much please share it in the fastest time.
Anonymous


Maria 6/23/2023 11:40:00 AM

correct answer is d for student.java program
IRELAND


Nagendra Pedipina 7/12/2023 9:10:00 AM

q:37 c is correct
INDIA


John 9/16/2023 9:37:00 PM

q6 exam topic: terramearth, c: correct answer: copy 1petabyte to encrypted usb device ???
GERMANY


SAM 12/4/2023 12:56:00 AM

explained answers
INDIA


Andy 12/26/2023 9:35:00 PM

plan to take theaws certified developer - associate dva-c02 in the next few weeks
SINGAPORE


siva 5/17/2023 12:32:00 AM

very helpfull
Anonymous


mouna 9/27/2023 8:53:00 AM

good questions
Anonymous


Bhavya 9/12/2023 7:18:00 AM

help to practice csa exam
Anonymous


Malik 9/28/2023 1:09:00 PM

nice tip and well documented
Anonymous


rodrigo 6/22/2023 7:55:00 AM

i need the exam
Anonymous